Suppr超能文献

通过双端口分析测定犬整个肺血管床的压力-流量和压力-容积关系。

Pressure-flow and pressure-volume relations in the entire pulmonary vascular bed of the dog determined by two-port analysis.

作者信息

Shoukas A A

出版信息

Circ Res. 1975 Dec;37(6):809-18. doi: 10.1161/01.res.37.6.809.

Abstract

To quantify the resistance and particularly the capacitance properties of the entire pulmonary vascular bed, isolated perfused lungs of nine dogs were studied. In each dog, with a fixed endotracheal pressure of 5 mm Hg, the arterial pressure-flow and pressure-volume relations were determined while venous pressure was fixed at constant values of 2, 5, and 8 mm Hg. In the same dogs, the venous pressure-flow and pressure-volume relations were also obtained when arterial pressure was fixed at constant values of 15 and 20 mm Hg. The arterial and venous pressure-flow relations could be regarded as linear around the physiological ranges of arterial and venous pressures; however, at very low pressures, these relations became nonlinear. The arterial and venous pressure-volume relations were also approximately linear within the physiological pressure ranges. The mean arterial compliance was 0.1798 ml/mm Hg kg-1 and was independent of venous pressures. The venous compliance values were 0.1236 and 0.0955 ml/mm Hg kg-1 for arterial pressures of 15 and 20 mm Hg, respectively. The sums of the arterial and venous compliances were 0.3034 and 0.2753 ml/mm Hg kg-1 for arterial pressures of 15 and 20 mm Hg, respectively. These values were nearly identical to the mean total compliance, 0.3265 ml/mm Hg kg-1, measured in a separate series of experiments in the same dogs. Therefore, the data obtained in these experiments using two-port analysis techniques represent the compliances and the resistance of the entire pulmonary vascular bed around the normal operating pressures and flows.

摘要

为了量化整个肺血管床的阻力,特别是电容特性,对9只狗的离体灌流肺进行了研究。在每只狗中,气管内压力固定为5 mmHg,在静脉压力固定为2、5和8 mmHg的恒定值时,测定动脉压力-流量和压力-容积关系。在同一只狗中,当动脉压力固定为15和20 mmHg的恒定值时,也获得了静脉压力-流量和压力-容积关系。在动脉和静脉压力的生理范围内,动脉和静脉压力-流量关系可视为线性;然而,在非常低的压力下,这些关系变为非线性。在生理压力范围内,动脉和静脉压力-容积关系也大致呈线性。平均动脉顺应性为0.1798 ml/mmHg kg-1,且与静脉压力无关。对于15和20 mmHg的动脉压力,静脉顺应性值分别为0.1236和0.0955 ml/mmHg kg-1。对于15和20 mmHg的动脉压力,动脉和静脉顺应性之和分别为0.3034和0.2753 ml/mmHg kg-1。这些值与在同一只狗的另一系列实验中测得的平均总顺应性0.3265 ml/mmHg kg-1几乎相同。因此,使用两端口分析技术在这些实验中获得的数据代表了正常工作压力和流量下整个肺血管床的顺应性和阻力。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验