Whenever the carbon/nitrogen ratio of a domestic wastewater is too low, full denitrification is difficult to obtain and an additional source of organic carbon has to be provided. Since loading conditions may vary appreciably over the diurnal cycle, depending on the weather and sewage conditions, dosing should be controlled by an adaptive regulator to keep into account the time-varying process dynamics. A fuzzy predictive controller is proposed in this paper and its performance is tested through numerical simulations. The new aspects brought forward are the use of an improved model for denitrification, the use of benchmark (i.e. thoroughly tested and standardised) input files and the conclusion about regulator performance in overall plant performance, in terms of carbon saving and discharge compliance.
每当生活污水的碳氮比过低时,就难以实现完全反硝化,因此必须提供额外的有机碳源。由于进水条件可能会因昼夜循环而有显著变化,具体取决于天气和污水状况,所以加药应通过自适应调节器进行控制,以考虑随时间变化的过程动态。本文提出了一种模糊预测控制器,并通过数值模拟对其性能进行了测试。所提出的新内容包括使用改进的反硝化模型、使用基准(即经过充分测试和标准化)输入文件,以及就碳节约和排放合规性而言,调节器性能对整个工厂性能的影响得出的结论。