Suppr超能文献

时间对氰基丙烯酸酯和复合正畸粘合剂剪切粘结强度的影响。

Effect of time on the shear bond strength of cyanoacrylate and composite orthodontic adhesives.

作者信息

Bishara Samir E, Laffoon John F, VonWald Leigh, Warren John

机构信息

Professor of Orthodontics, College of Dentistry, The University of Iowa, Iowa City, IA 52242, USA.

出版信息

Am J Orthod Dentofacial Orthop. 2002 Mar;121(3):297-300. doi: 10.1067/mod.2002.121012.

Abstract

The purpose of this study was to compare the effects of time on the shear bond strength of a cyanoacrylate system and a composite adhesive system (1) within half an hour after bonding the bracket to the tooth, and (2) after 24 hours from the time of bonding when the adhesive had achieved most of its bond strength. Eighty freshly extracted molars were collected and stored in a solution of 0.1% (weight/volume) thymol. The teeth were cleansed, polished, and randomly separated into 4 groups: (I), cyanoacrylate adhesive debonded within one-half hour from initial bonding; (II), cyanoacrylate adhesive debonded after 24 hours immersion in deionized water at 37 degrees C; (III), composite adhesive debonded within one-half hour from initial bonding; (IV), composite adhesive debonded after 24 hours immersion in deionized water at 37 degrees C. The results of the analysis of variance comparing the 4 experimental groups (F = 12.68) indicated significant differences between them (P =.0001). The composite adhesive at 24 hours had significantly greater shear bond strength than did the other 3 groups. In general, the shear bond strengths were greater in the 2 groups debonded after 24 hours. This was true for both the cyanoacrylate ((-)x 7.1 +/- 3.3 megaPascals [MPa]) and the composite ((-)x 10.4 +/- 2.8 MPa) adhesives. On the other hand, the shear bond strength was significantly lower in the 2 groups debonded within one-half hour of their initial bonding. The bond strength of the cyanoacrylate adhesive ((-)x 5.8 +/- 2.4 MPa) was not significantly different from that of the composite ((-)x 5.2 +/- 2.9 MPa) adhesive. Our findings indicated that the cyanoacrylate and the composite adhesives tested have clinically adequate shear bond strengths at half an hour and at 24 hours after initial bonding. The clinician needs to consider the properties of each adhesive: eg, the need to use a curing light and the ability to have more working time with the composite adhesive versus no light but only a 5-second working time before the cyanoacrylate adhesive starts to set.

摘要

本研究的目的是比较时间对氰基丙烯酸酯系统和复合粘合剂系统剪切粘结强度的影响,(1)在将托槽粘结到牙齿后的半小时内,以及(2)在粘结后24小时,此时粘合剂已达到其大部分粘结强度。收集80颗新鲜拔除的磨牙,并保存在0.1%(重量/体积)百里酚溶液中。对牙齿进行清洁、抛光,然后随机分为4组:(I),氰基丙烯酸酯粘合剂在初始粘结后半小时内脱粘;(II),氰基丙烯酸酯粘合剂在37℃的去离子水中浸泡24小时后脱粘;(III),复合粘合剂在初始粘结后半小时内脱粘;(IV),复合粘合剂在37℃的去离子水中浸泡24小时后脱粘。比较4个实验组的方差分析结果(F = 12.68)表明它们之间存在显著差异(P = 0.0001)。24小时时的复合粘合剂的剪切粘结强度明显高于其他3组。一般来说,在24小时后脱粘的2组中,剪切粘结强度更高。氰基丙烯酸酯(-x 7.1±3.3兆帕[MPa])和复合(-x 10.4±2.8 MPa)粘合剂都是如此。另一方面,在初始粘结后半小时内脱粘的2组中,剪切粘结强度明显较低。氰基丙烯酸酯粘合剂(-x 5.8±2.4 MPa)的粘结强度与复合(-x 5.2±2.9 MPa)粘合剂的粘结强度无显著差异。我们的研究结果表明,所测试的氰基丙烯酸酯和复合粘合剂在初始粘结后半小时和24小时具有临床上足够的剪切粘结强度。临床医生需要考虑每种粘合剂的特性:例如,使用固化灯的必要性,以及与复合粘合剂相比有更多工作时间的能力,而氰基丙烯酸酯粘合剂在开始凝固前不需要光照,但只有5秒的工作时间。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验