Suppr超能文献

三种正畸粘合剂体外测试的氟化物释放方案比较

Comparison of fluoride release protocols for in-vitro testing of 3 orthodontic adhesives.

作者信息

Wheeler Arthur W, Foley Timothy F, Mamandras Antonios

机构信息

Division of Graduate Orthodontics, Faculty of Medicine and Dentistry, University of Western Ontario, Dental Science Building, London, Ontario, Canada N6A 5C1.

出版信息

Am J Orthod Dentofacial Orthop. 2002 Mar;121(3):301-9. doi: 10.1067/mod.2002.120160.

Abstract

The objective of this study was to compare the fluoride release of 3 orthodontic adhesives using disks and bracketed teeth with different storage protocols. The adhesives used were a resin-modified glass ionomer (RMGI) (Fuji Ortho LC; GC America, Aslip, Ill), a polyacid-modified composite resin (PMCR)(Assure; Reliance Orthodontic Products, Itasca, Ill), and a composite control, Transbond XT (3M Unitek, Monrovia, Calif). Metal brackets were bonded to the buccal and lingual surfaces of 120 extracted human premolars. Five plastic containers holding 4 teeth (8 brackets) were used for each adhesive protocol. The samples were stored in containers holding 4 mL of deionized water at 37 degrees C for 28 and 84 days for the brackets and disks, respectively. The bracketed samples released larger initial amounts of fluoride compared with the disk samples during the first 5 to 6 days for both fluoride-releasing adhesives. The PMCR (Assure) released more fluoride (mg/cm(2)/day) than did the RMGI (Fuji Ortho LC) in all protocols with the exception of daily protocols when values diminished below the RMGI values near the 24th day and between the 56th and the 70th days for the bracketed and disk samples, respectively. Inconsistent values for fluoride release were noted in the bracket and disk samples when compared with daily versus cumulative water changes. Daily water changes revealed higher fluoride release levels (brackets), but this trend was not evident in the disk samples. Daily water changes may yield more clinically relevant data on fluoride release.

摘要

本研究的目的是比较3种正畸粘合剂在使用圆盘和带托槽牙齿并采用不同储存方案时的氟释放情况。所使用的粘合剂为树脂改性玻璃离子体(RMGI)(Fuji Ortho LC;美国GC公司,伊利诺伊州阿斯利普)、聚酸改性复合树脂(PMCR)(Assure;美国Reliance正畸产品公司,伊利诺伊州伊塔斯卡)以及复合对照品Transbond XT(3M Unitek公司,加利福尼亚州蒙罗维亚)。将金属托槽粘结到120颗拔除的人类前磨牙的颊面和舌面。每种粘合剂方案使用5个装有4颗牙齿(8个托槽)的塑料容器。对于托槽和圆盘,样品分别在装有4 mL去离子水的容器中于37℃储存28天和84天。在最初的5至6天内,对于两种释放氟的粘合剂,带托槽的样品比圆盘样品释放出更大初始量的氟。除了每日方案外,在所有方案中,PMCR(Assure)释放的氟(mg/cm²/天)均比RMGI(Fuji Ortho LC)多,在每日方案中,对于带托槽和圆盘样品,分别在第24天左右以及第56天至第70天之间,其释放量降至低于RMGI的值。与每日换水和累积换水相比,在带托槽和圆盘样品中观察到氟释放值不一致。每日换水显示出更高的氟释放水平(托槽),但这种趋势在圆盘样品中不明显。每日换水可能会产生更多关于氟释放的临床相关数据。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验