Suppr超能文献

新鲜冰冻血浆和血小板使用的质量指标。

Quality indicators of fresh frozen plasma and platelet utilization.

作者信息

Novis David A, Renner Stephen, Friedberg Richard C, Walsh Molly K, Saladino Andrew J

机构信息

Department of Pathology, Wentworth-Douglass Hospital, Dover, NH 03820, USA.

出版信息

Arch Pathol Lab Med. 2002 May;126(5):527-32. doi: 10.5858/2002-126-0527-QIOFFP.

Abstract

OBJECTIVE

To determine the normative rates of expiration and wastage for units of fresh frozen plasma (FFP) and platelets (PLTs) in hospital communities throughout the United States, and to examine hospital blood bank practices associated with more desirable (lower) rates.

DESIGN

In 3 separate studies, participants in the College of American Pathologists Q-Probes laboratory quality improvement program collected data retrospectively on the numbers of units of FFP and PLTs that expired (outdated) prior to being used and that were wasted due to mishandling. Participants also completed questionnaires describing their hospitals' and blood banks' laboratory and transfusion practices.

SETTING AND PARTICIPANTS

One thousand six hundred thirty-nine public and private institutions, more than 80% of which were known to be located in the United States.

MAIN OUTCOME MEASURES

Quality indicators of FFP and PLT utilization: the rates of expiration and wastage of units of FFP and PLTs.

RESULTS

Participants submitted data on 8 981 796 units of FFP and PLTs. In all 3 studies, aggregate combined FFP and PLT expiration rates ranged from 5.8% to 6.4% and aggregate combined FFP and PLT wastage rates ranged from 2.0% to 2.5%. Among the top-performing 10% of participants (90th percentile and above), FFP and PLT expiration rates were 0.6% or lower and FFP and PLT wastage rates were 0.5% or lower. Among the bottom-performing 10% of participants (10th percentile and below), expiration rates were 13.8% or higher and wastage rates were 6.8% or higher. We were unable to associate selected hospital characteristics or blood bank practices with lower rates of FFP and PLT utilization.

CONCLUSIONS

The rates of FFP and PLT expiration and wastage vary greatly among hospitals in the United States. Hospital blood bank personnel are capable of achieving FFP and PLT expiration and wastage rates below 1%.

摘要

目的

确定美国各地医院团体中新鲜冰冻血浆(FFP)和血小板(PLTs)单位的过期率和浪费率规范,并检查与更理想(更低)率相关的医院血库操作。

设计

在3项独立研究中,美国病理学家学会Q-Probes实验室质量改进项目的参与者回顾性收集了FFP和PLTs单位在使用前过期(过时)以及因处理不当而浪费的数量数据。参与者还完成了描述其医院和血库实验室及输血操作的问卷。

地点和参与者

1639家公立和私立机构,其中80%以上已知位于美国。

主要观察指标

FFP和PLT使用的质量指标:FFP和PLTs单位的过期率和浪费率。

结果

参与者提交了8981796单位FFP和PLTs的数据。在所有3项研究中,FFP和PLT综合过期率在5.8%至6.4%之间,FFP和PLT综合浪费率在2.0%至2.5%之间。在表现最佳的10%参与者(第90百分位数及以上)中,FFP和PLT过期率为0.6%或更低,FFP和PLT浪费率为0.5%或更低。在表现最差的10%参与者(第10百分位数及以下)中,过期率为13.8%或更高,浪费率为6.8%或更高。我们无法将选定的医院特征或血库操作与较低的FFP和PLT使用率联系起来。

结论

美国各医院的FFP和PLT过期率和浪费率差异很大。医院血库人员能够将FFP和PLT过期率和浪费率降至1%以下。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验