Abstract

PURPOSE

To evaluate the reliability of binocular vision measurements used in the classification of convergence insufficiency.

METHODS

Two examiners tested 20 fifth and sixth graders in a school setting who passed a screening of visual acuity, refraction, and binocularity. The tests, conducted using a standard protocol, consisted of von Graefe near heterophoria (NH), phorometric positive fusional vergence (PFV), nearpoint of convergence (NPC), and monocular pushup accommodative amplitude (AA). Each examiner measured each child three consecutive times for each test, on two separate occasions, spaced approximately 1 week apart. Intraexaminer and interexaminer agreement was assessed using intraclass correlation coefficients (ICC), the median absolute difference (MAD), and the coefficient of repeatability (COR).

RESULTS

The within-session reliability of the NH (ICC: 0.95 to 0.99), NPC (ICC: 0.94 to 0.98), and AA (ICC: 0.88 to 0.95) were good, whereas the PFV was less reliable (ICC: 0.71 to 0.94). The intraexaminer reliability between sessions was good for the NPC (ICC: 0.92 and 0.89), less reliable for NH (ICC: 0.81 and 0.81) and AA (ICC: 0.89 and 0.69), and much less reliable for PFV break (ICC: 0.59 and 0.53). Typical between-session PFV differences (MAD) were between 3 and 4 delta, whereas the COR differences were as large as 12 delta.

CONCLUSIONS

Three of the four measures (NH, NPC, and AA) often used in the classification of convergence insufficiency generally have good within-session and between-session reliability. The PFV break was found to have only fair reliability with clinically significant differences between sessions. The large potential test-retest differences found could complicate clinical decision-making in regards to diagnosis and treatment.

摘要

目的

评估用于集合不足分类的双眼视觉测量的可靠性。

方法

两名检查者在学校环境中对20名五、六年级学生进行测试,这些学生通过了视力、屈光和双眼视功能筛查。使用标准方案进行的测试包括冯·格拉夫近距离隐斜(NH)、验光正融像性聚散(PFV)、集合近点(NPC)和单眼上推调节幅度(AA)。每位检查者在两个不同的场合,每次测试对每个孩子连续测量三次,间隔约1周。使用组内相关系数(ICC)、中位数绝对差(MAD)和重复性系数(COR)评估检查者内和检查者间的一致性。

结果

NH(ICC:0.95至0.99)、NPC(ICC:0.94至0.98)和AA(ICC:0.88至0.95)的单次测量可靠性良好,而PFV的可靠性较低(ICC:0.71至0.94)。检查者间不同测量时段的可靠性,NPC良好(ICC:0.92和0.89),NH(ICC:0.81和第0.81)和AA(ICC:0.89和0.69)较差,PFV破裂的可靠性更差(ICC:0.59和0.53)。不同测量时段PFV的典型差异(MAD)在3至4棱镜度之间,而COR差异高达12棱镜度。

结论

集合不足分类中常用的四项测量指标中的三项(NH、NPC和AA)通常在单次测量和不同测量时段具有良好的可靠性。发现PFV破裂的可靠性仅为中等,不同测量时段存在临床显著差异。发现的较大的重测差异可能会使诊断和治疗方面的临床决策复杂化。