De Smet E, Jacobs R, Gijbels F, Naert I
Department of Prosthetic Dentistry, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Catholic University Leuven, Belgium.
Dentomaxillofac Radiol. 2002 May;31(3):176-81. doi: 10.1038/sj/dmfr/4600694.
To determine the accuracy and reliability of radiographic methods for assessment of the marginal bone level around oral implants in human cadavers.
In three human cadavers two implants were placed according to the Instruction Manual for the Brånemark System. One implant was installed in the canine and one in the premolar region of the left mandible. For each implant, conventional and digital intra-oral paralleling radiography were performed. Digital images were printed with a Kodak 1200 Distributed Medical Imaging printer on blue transparent film, glossy and plain paper. Furthermore, digital scanographic, panoramic and tomographic images were taken with the Cranex Tome multimodal X-ray unit and printed on Agfa Drystar TM 1 B transparent films. All images were evaluated by five dental specialists. Data were statistically compared with real measurements of the marginal bone level on the human cadavers, performed by the same group of observers. Intra- and inter-observer variability were determined.
Digital intra-oral images on glossy paper showed the smallest absolute difference between real and measured bone level, followed by digital intra-oral images on film and on plain paper, conventional intra-oral images on analogue film, panoramic, scanographic and tomographic images on film. The difference between real and radiographic measurements was not statistically significant (P>0.05) for all radiographic techniques. Intra- and inter-observer reproducibility was high for all techniques.
The selected imaging techniques showed an acceptable accuracy for peri-implant bone level measurements with an overall error of less than 0.5 mm. Intra-oral images showed the smallest absolute differences.
确定用于评估人体尸体口腔种植体周围边缘骨水平的放射学方法的准确性和可靠性。
在三具人体尸体中,按照布兰emark系统的使用说明书植入两枚种植体。一枚种植体植入左下颌犬齿区,另一枚植入前磨牙区。对每枚种植体进行传统口腔平行投照和数字化口腔平行投照。数字化图像用柯达1200分布式医学成像打印机打印在蓝色透明胶片、光面纸和普通纸上。此外,使用克兰ex Tome多模态X射线装置拍摄数字化扫描断层、全景和断层图像,并打印在爱克发Drystar TM 1 B透明胶片上。所有图像由五位牙科专家进行评估。数据与同一组观察者对人体尸体边缘骨水平的实际测量值进行统计学比较。确定观察者内和观察者间的变异性。
光面纸上的数字化口腔内图像显示实际骨水平与测量骨水平之间的绝对差异最小,其次是胶片和普通纸上的数字化口腔内图像、模拟胶片上的传统口腔内图像、胶片上的全景、扫描断层和断层图像。所有放射学技术的实际测量值与放射学测量值之间的差异无统计学意义(P>0.05)。所有技术的观察者内和观察者间再现性均较高。
所选成像技术在种植体周围骨水平测量中显示出可接受的准确性,总体误差小于0.5毫米。口腔内图像显示的绝对差异最小。