An inexpensive device was created for computed tomographic (CT)-guided stereotactic biopsy of the canine brain. The accuracy of the device was tested using 16, formalin-perfused, canine head specimens. For each dog, a 6-inch biopsy needle was guided into pituitary gland and caudate nucleus targets. Needle tracks were measured using the CT computer and infused with tissue staining solution. Hit success and actual needle track lengths were determined from sliced brain specimens. The device enabled accurate orientation and placement of the canine head in the slice plane, such that progressive penetration of the biopsy needle could be monitored. The caudate nucleus was hit 12/16 times (75% accuracy) and the pituitary gland 15.5/16 times (98.6% accuracy). Hit proportions for the two targets did not differ (P < 0.05). A significant difference was found between CT and actual track length for both targets (P < 0.01). This was attributed to incomplete staining of the bevel portion of the needle track.

摘要

制造了一种用于犬脑计算机断层扫描(CT)引导立体定向活检的廉价设备。使用16个经福尔马林灌注的犬头部标本测试了该设备的准确性。对于每只狗,将一根6英寸的活检针引导至垂体和尾状核靶点。使用CT计算机测量针道,并注入组织染色溶液。从切片脑标本中确定命中成功率和实际针道长度。该设备能够在切片平面上准确地对犬头部进行定位和放置,从而可以监测活检针的逐步刺入。尾状核命中12/16次(准确率75%),垂体命中15.5/16次(准确率98.6%)。两个靶点的命中比例没有差异(P<0.05)。两个靶点的CT测量针道长度与实际针道长度之间均存在显著差异(P<0.01)。这归因于针道斜面部分染色不完全。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验