Shields Steven R, Chen Peng
Saint Louis University Eye Institute, Saint Louis, Missouri 63104, USA.
J Glaucoma. 2002 Jun;11(3):203-8. doi: 10.1097/00061198-200206000-00007.
To describe the outcomes of combining cyclophotocoagulation and tube-shunt glaucoma drainage implants, either sequentially or simultaneously, for the control of refractory glaucomas.
A retrospective review was conducted of all patients that had been treated at our institute with both cyclophotocoagulation and a tube-shunt glaucoma drainage implant in the same eye between January 1996 and June 2000. Preoperative and postoperative intraocular pressure, number of glaucoma medications, vision, and complications data were collected for each eye.
A total of 10 eyes of 9 patients met the study criteria. The minimum follow-up period after the last surgery was 15 months. Intraocular pressures were reduced from 28.5 +/- 7.2 mm Hg preoperatively to 13.9 +/- 5.4 mm Hg postoperatively at 15 months (P < 0.000, n = 9). Medications were reduced from 2.7 +/- 1.2 preoperatively to 0.3 +/- 0.5 postoperatively at 15 months (P < 0.000, n = 9). Of the eight eyes with measurable Snellen acuity, postoperative vision decreased two or more lines in five eyes (63%). Complications included transient hypotony (one eye), transient serous choroidal detachment (two eyes), cystoid macular edema (two eyes), corneal edema (three eyes), and panuveitis with chronic hypotony and traction retinal detachment (one eye).
Combining cyclophotocoagulation with tube-shunt glaucoma drainage implants can effectively reduce intraocular pressure and number of glaucoma medications needed to achieve target intraocular pressure goals. Further study is needed to determine the safety of this combined approach compared with other available options to manage refractory glaucomas.