Hall M C, Fenelon A R, McDonald R D, Steel J D
Aust Vet J. 1975 Dec;51(12):547-53. doi: 10.1111/j.1751-0813.1975.tb09377.x.
Different techniques for monitoring cardiac responses to exercise in the horse have been described and evaluated. For experimental work of this type in a normal training and racing environment, the electrode system described when used with a portable magnetic tape recording system provided the best means of obtaining useful and reproducible data.