Suppr超能文献

Pharmacokinetics of mono-3'- and mono-4'-0-(beta-hydroxyethyl)-rutoside derivatives, after single doses of Venoruton powder in healthy volunteers.

作者信息

Kienzler J-L, Sallin D, Schifflers M-H, Ghika A

机构信息

Department of Clinical Research, PO Box 269, 1260 Nyon 1, Switzerland.

出版信息

Eur J Clin Pharmacol. 2002 Sep;58(6):395-402. doi: 10.1007/s00228-002-0472-3. Epub 2002 Aug 2.

Abstract

BACKGROUND

Venoruton is a standardised mixture of O-(beta-hydroxyethyl) rutosides (HR) used for the relief of oedema and related symptoms in patients with chronic venous insufficiency. OBJECTIVES. The primary objective was to evaluate the pharmacokinetic parameters, in particular the rate and extent of absorption (bioavailability) of two markers of Venoruton: mono-3'-HR and mono-4'-HR derivatives [glucuroconjugated forms (HG)], analysed in their deconjugated form as O-(beta-hydroxyethyl)-quercetin (HQ): mono-3'-HQ and mono-4'-HQ, and to investigate dose proportionality. A secondary objective was to evaluate the general safety of the different dosages.

METHODS

In this open, single-dose, randomised, four-way, crossover study, 16 healthy volunteers received four different oral doses of Venoruton powder (0.5, 1, 2 or 4 g). Eighteen blood samples were obtained between 10 min pre-dose and 120 h post-dose.

RESULTS

Peak plasma concentration (C(max)) and area under the plasma concentration-time curve (AUC) of mono-3'-HQ were or tended to be proportional to the dose between 1 g and 4 g. The dose proportionality could be extended to the 0.5-g dose, although C(max) and AUC were not always estimable at that dose level (due to the low number of data points above the limit of quantification). For mono-4'-HQ, the increase of C(max) and AUC was also or tended to be proportional to the dose over the whole tested range (0.5-4 g). Time to peak concentration of both Venoruton derivatives remained unaffected by the administered dose. The elimination half-life of both molecules was very similar with the three highest doses. It was shorter with the 0.5-g dose but was not accurately estimated (or even not estimable in some subjects) due to the low number of points above the limit of quantification.

CONCLUSIONS

The bioavailability of both Venoruton derivatives (mono-3'-HQ and mono-4'-HQ) tended to be proportional to the dose. The rate of appearance and the elimination half-life of both molecules were not modified with the administered dose. The different doses of the study medication were safe and well tolerated. Mono-3'-HQ and mono-4'-HQ are therefore new bioanalytic and pharmacokinetic markers for Venoruton.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验