Morocutti G, Gelsomino S, Spedicato L, Frassani R, Bernardi G, Da Col P, Paparella G, Fioretti P, Livi U
Department of Cardiovascular Sciences, General Hospital S. Maria della Misericordia, Udine, Italy.
Cardiovasc Surg. 2002 Aug;10(4):328-32. doi: 10.1016/s0967-2109(02)00019-4.
The aim of this study was to assess the utility of intraoperative transesophageal echocardiography (TEE) in the evaluation of patients undergoing aortic valve replacement with the CryoLife-O'Brien (CLOB) Stentless Porcine Aortic Bioprosthesis.
Between May 1994 and March 1995, 26 patients (15 men, mean age 68.4+/-10.78 years) had a CLOB valve in the aortic position. Transprosthetic gradients and valve regurgitation were detected by intraoperative TEE. Prosthetic regurgitation and transvalvular gradients were evaluated at six-month intervals using transthoracic echo-Doppler (TTE).
The majority of implants resulted in low gradients (83.7%), with only four patients exhibiting a moderate gradient (15.3%). Color flow Doppler imaging showed central aortic regurgitation in only four of 25 patients (trivial, n=4; mild, n=1). There was one paravalvular leak (trivial, n=1). At follow-up examination (mean 37+/-12 months), 24 of 25 patients exhibited low mean gradients (7.25+/-2.81 mmHg). At follow-up one patient who had low velocities in the LVOT at perioperative evaluation exibited a moderate gradient (45 mmHg) with an effective orifice area of 0.8-0.9 cm(2).
Intraoperative TEE was effective in assessing prosthetic stentless valve function.
本研究的目的是评估术中经食管超声心动图(TEE)在评价接受使用CryoLife - O'Brien(CLOB)无支架猪主动脉生物瓣膜进行主动脉瓣置换术患者中的应用价值。
1994年5月至1995年3月期间,26例患者(15例男性,平均年龄68.4±10.78岁)在主动脉位置植入了CLOB瓣膜。术中通过TEE检测跨瓣膜压差和瓣膜反流情况。使用经胸超声多普勒(TTE)每隔6个月评估人工瓣膜反流和跨瓣膜压差。
大多数植入导致低压差(83.7%),只有4例患者表现为中度压差(15.3%)。彩色血流多普勒成像显示25例患者中仅4例存在中心主动脉反流(微量,n = 4;轻度,n = 1)。有1例瓣周漏(微量,n = 1)。在随访检查(平均37±12个月)时,25例患者中有24例表现为低平均压差(7.25±2.81 mmHg)。在随访中,1例在围手术期评估时左心室流出道流速较低的患者表现为中度压差(45 mmHg),有效瓣口面积为0.8 - 0.9 cm²。
术中TEE在评估人工无支架瓣膜功能方面是有效的。