Mallet E, Brunelle P
Clin Chim Acta. 1975 Oct 1;64(1):11-8. doi: 10.1016/0009-8981(75)90138-2.
A radio-immunoassay method of parathyroid hormone in peripheral circulation is described utilizing both commercially available antibody and bovine PTH preparation for iodination. As a standard, the bovine PTH delivered from the Medical Research Council (MRC) is used. Antibody-bound hormone is separated from free hormone by solid phase immunoprecipitation. Good cross reactivity of this antiserum to human PTH is shown, but because of the lack of human standard, it is demonstrated, that results may be expressed in reference to the MRC bovine hormone. The coefficient of interassay variation is 12% and the detection limit is 300 pg/ml. In every healthy subject, immunoreactive PTH is detected: the normal distribution range (n equals 31) was 400 to 1800 pg/ml. Two hypoparathyroid patients have undetectable levels. There is a slight overlap between normal and those from hyperparathyroid patients. The present method gives results expressed in international units (MRC standard). The reliability of the PTH radio-immunoassay is dependent on the characteristics of the antiserum. This method provides a basis for the establishment of PTH values with the possibility of comparing results in health and disease.
本文描述了一种外周循环中甲状旁腺激素的放射免疫测定方法,该方法使用市售抗体和用于碘化的牛甲状旁腺激素制剂。以医学研究委员会(MRC)提供的牛甲状旁腺激素作为标准品。通过固相免疫沉淀将抗体结合的激素与游离激素分离。结果表明,该抗血清与人甲状旁腺激素具有良好的交叉反应性,但由于缺乏人标准品,结果可能以相对于MRC牛激素的形式表示。批间变异系数为12%,检测限为300 pg/ml。在每一位健康受试者中均检测到免疫反应性甲状旁腺激素:正常分布范围(n = 31)为400至1800 pg/ml。两名甲状旁腺功能减退患者的甲状旁腺激素水平检测不到。正常人与甲状旁腺功能亢进患者的结果略有重叠。本方法给出的结果以国际单位(MRC标准)表示。甲状旁腺激素放射免疫测定的可靠性取决于抗血清的特性。该方法为建立甲状旁腺激素值提供了基础,使得能够比较健康和疾病状态下的结果。