Suppr超能文献

通过酶联免疫吸附测定法测得的尿8-氧代-7,8-二氢-2'-脱氧鸟苷值与通过高效液相色谱-电化学检测法测得的结果具有良好的相关性。

Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine values measured by an ELISA correlated well with measurements by high-performance liquid chromatography with electrochemical detection.

作者信息

Yoshida Rie, Ogawa Yasutaka, Kasai Hiroshi

机构信息

National Institute of Industrial Health, Kawasaki 214-8585, Japan.

出版信息

Cancer Epidemiol Biomarkers Prev. 2002 Oct;11(10 Pt 1):1076-81.

Abstract

Measurement of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxo-dG) has recently become more popular as a means of assessing oxidative stress in the human body. Although using high-performance liquid chromatography with electrochemical detection (HPLC-ECD) is a reliable method of measuring 8-oxo-dG, easier and simpler alternative methods may be preferred, if they are quantitatively accurate. The ELISA method is the likeliest candidate for a useful alternative. Anti-8-oxo-dG monoclonal antibody N45.1 has been shown to have better specificity for 8-oxo-dG than other anti-8-oxo-dG antibodies, but the urinary 8-oxo-dG values measured by ELISA using N45.1 have been claimed to only weakly correlate with the values obtained by HPLC-ECD. Because the commercial ELISA kit has been improved, we compared the urinary 8-oxo-dG values measured by the ELISA with the values obtained by HPLC-ECD. We sampled the urine of 72 healthy Japanese individuals and measured their urinary 8-oxo-dG levels by the ELISA with appropriate controls and by HPLC-ECD. When X was defined as the values of 8-oxo-dG measured by HPLC-ECD, and Y was defined as the values of 8-oxo-dG measured by the ELISA, simple regression analysis showed the most likely relationship to be Y = 1.83X + 0.8. The correlation coefficient was 0.88, which indicated a good correlation between X and Y. These results show that the ELISA can be applied to studies comparing relative urinary 8-oxo-dG values among several groups, if the studies do not require determination of the exact concentration of 8-oxo-dG in urine.

摘要

测量尿中8-氧代-7,8-二氢-2'-脱氧鸟苷(8-氧代-dG)最近作为评估人体氧化应激的一种手段变得越来越流行。尽管使用高效液相色谱-电化学检测法(HPLC-ECD)是测量8-氧代-dG的可靠方法,但如果定量准确,可能更倾向于使用更简便的替代方法。酶联免疫吸附测定(ELISA)方法最有可能成为一种有用的替代方法。抗8-氧代-dG单克隆抗体N45.1已被证明对8-氧代-dG的特异性比其他抗8-氧代-dG抗体更好,但有人声称使用N45.1通过ELISA测量的尿8-氧代-dG值与通过HPLC-ECD获得的值仅呈弱相关。由于商用ELISA试剂盒已得到改进,我们比较了通过ELISA测量的尿8-氧代-dG值与通过HPLC-ECD获得的值。我们采集了72名健康日本个体的尿液,并通过带有适当对照的ELISA和HPLC-ECD测量了他们的尿8-氧代-dG水平。当将X定义为通过HPLC-ECD测量的8-氧代-dG值,将Y定义为通过ELISA测量的8-氧代-dG值时,简单回归分析显示最可能的关系为Y = 1.83X + 0.8。相关系数为0.88,表明X和Y之间具有良好的相关性。这些结果表明,如果研究不需要测定尿中8-氧代-dG的确切浓度,ELISA可应用于比较几组之间相对尿8-氧代-dG值的研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验