Logan John W, Urban Jeffry T, Walls Jamie D, Lim Kwang Hun, Jerschow Alexej, Pines Alexander
Materials Sciences Division, 1 Cyclotron Rd, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA.
Solid State Nucl Magn Reson. 2002 Sep-Nov;22(2-3):97-109. doi: 10.1006/snmr.2002.0084.
Additional experimental evidence of rotary resonance effects for multiple-quantum coherence conversion in a spin-5/2 system is presented. Two-dimensional plots of the relative efficiency of MQ excitation and conversion are given as a function of radio frequency (rf) amplitude and pulse width. Data are presented for the excitation of five-quantum coherence (5QC), as well as for 5QC to three-quantum coherence (3QC) conversion, 5QC to IQC (the central transition coherence) conversion, and 3QC to IQC conversion. A two-fold increase in the signal-to-noise ratio is achieved by substituting low amplitude rf pulses in place of hard rf pulses for 5QC excitation and 5QC to 3QC conversion in a mixed multiple-quantum magic angle spinning (MAS) (MMQMAS) experiment. The anisotropic line shape for the low-amplitude rf pulse version of the MMQMAS experiment was observed to be distorted from the MAS line shape. The cause and implications of the distortion are discussed.