Müller Frauke, Heath M Robin, Ferman Anthony M, Davis Graham R
Department of Adult Oral Health, St Bartholomew's and the Royal London School of Medicine and Dentistry, London.
Int J Prosthodont. 2002 Nov-Dec;15(6):553-8.
Suction is achieved when complete dentures are first fitted, but it fades during the months following insertion, when it is increasingly complemented by muscular denture control. The aim of this study was therefore to investigate the extent to which patterns of mastication are altered by experimental failure of physical retention.
Seven edentulous volunteers had maxillary replica dentures made, with fine tubes incorporated so that alternating positive and negative air pressure could be generated under the fitting surface. Mandibular movements, EMG, and pressure under the denture base were recorded during unilateral chewing.
The change of physical retention passed undetected by all subjects; they continued chewing apparently undisturbed. However, during air injection, the mandibular excursions were slightly slower (nonsignificant) and demonstrated a reduced variance (P < or = .05). The muscle activity showed significantly longer bursts (P < or = .05), and peak activity occurred later in the cycle (nonsignificant).
Sudden failure of denture retention seems to initiate an immediate and effective modulation of centrally generated muscular activity patterns.
全口义齿初次佩戴时可获得吸附力,但在戴入后的几个月内吸附力会逐渐减弱,此时肌肉对义齿的控制作用会日益增强。因此,本研究旨在调查物理固位失败对咀嚼模式的改变程度。
为7名无牙颌志愿者制作上颌复制义齿,义齿内植入细管,以便在义齿贴合面下方产生正负交替的气压。在单侧咀嚼过程中记录下颌运动、肌电图(EMG)以及义齿基托下方的压力。
所有受试者均未察觉到物理固位的变化;他们继续咀嚼,未受明显干扰。然而,在注入空气时,下颌运动幅度稍慢(无统计学意义),且变化幅度减小(P≤0.05)。肌肉活动的爆发时间显著延长(P≤0.05),且峰值活动在周期后期出现(无统计学意义)。
义齿固位突然失败似乎会立即引发对中枢产生的肌肉活动模式的有效调节。