Suppr超能文献

叠加电刺激对感知不适以及扭矩增量大小和变异性的影响。

Effects of superimposed electrical stimulation on perceived discomfort and torque increment size and variability.

作者信息

Miller Michael, Downham David, Lexell Jan

机构信息

Department of Physical Therapy, Lund University, Box 5134, SE-22005 Lund, Sweden.

出版信息

Muscle Nerve. 2003 Jan;27(1):90-8. doi: 10.1002/mus.10289.

Abstract

Superimposed electrical stimulation techniques can be used to detect central activation failure (CAF), that is, incomplete central nervous system recruitment or suboptimal activation of motor units. The purpose of this study was to evaluate the effects of two stimulation parameters on perceived discomfort and torque increment size and variability. Discomfort was evaluated using a visual analog scale (0-100 mm) for pain. The rectus femoris muscle of the dominant leg of 24 young healthy men was stimulated during submaximal (80% maximal) voluntary contractions. The size and variability of torque increments and perceived discomfort were assessed following stimulation with: (1) pulse trains (100 HZ, 150 V, 0.2-ms pulse duration) of different lengths (50 ms and 100 ms); and (2) pulse trains (100 HZ, 100 ms, 150 V) with different pulse durations (0.2 ms and 0.1 ms). Pulse trains of 100 ms generated larger torque increments and produced less variability, but caused more discomfort than pulse trains of 50 ms. Average discomfort ratings for pulse trains of 100 ms were 43.1 mm, and of 50 ms were 53.2 mm. There was no difference in torque increment size or in variability between pulse trains with pulse durations of 0.1 ms and 0.2 ms, whereas discomfort was less for the shorter pulse durations; average discomfort ratings were 53.1 mm and 58.1 mm for pulse durations of 0.1 ms and 0.2 ms, respectively. Thus, the appropriate selection of stimulation parameters can reduce discomfort but maintain the ability to detect CAF.

摘要

叠加电刺激技术可用于检测中枢激活失败(CAF),即中枢神经系统募集不完全或运动单位激活不理想。本研究的目的是评估两种刺激参数对感知不适以及扭矩增加的大小和变异性的影响。使用视觉模拟量表(0 - 100毫米)评估疼痛程度来衡量不适。在24名年轻健康男性优势腿的股直肌进行次最大(最大力量的80%)自主收缩期间进行刺激。在以下刺激后评估扭矩增加的大小和变异性以及感知不适:(1)不同长度(50毫秒和100毫秒)的脉冲序列(100赫兹、150伏、0.2毫秒脉冲持续时间);(2)不同脉冲持续时间(0.2毫秒和0.1毫秒)的脉冲序列(100赫兹、100毫秒、150伏)。100毫秒的脉冲序列产生更大的扭矩增加且变异性更小,但比50毫秒的脉冲序列引起更多不适。100毫秒脉冲序列的平均不适评分为43.1毫米,50毫秒脉冲序列的平均不适评分为53.2毫米。脉冲持续时间为0.1毫秒和0.2毫秒的脉冲序列在扭矩增加大小或变异性方面没有差异,而较短脉冲持续时间的不适较小;0.1毫秒和0.2毫秒脉冲持续时间的平均不适评分分别为53.1毫米和58.1毫米。因此,适当选择刺激参数可以减少不适,但保持检测CAF的能力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验