大鼠急性脑缺血的磁共振成像T(1rho) 共振与非共振研究

On- and off-resonance T(1rho) MRI in acute cerebral ischemia of the rat.

作者信息

Gröhn Olli H J, Mäkelä Heidi I, Lukkarinen Jouko A, DelaBarre Lance, Lin Joseph, Garwood Michael, Kauppinen Risto A

机构信息

Department of Biomedical NMR, National Bio-NMR Facility, A.I. Virtanen Institute for Molecular Sciences, University of Kuopio, Kuopio, Finland.

出版信息

Magn Reson Med. 2003 Jan;49(1):172-6. doi: 10.1002/mrm.10356.

Abstract

The ability of on-resonance T(1rho) (T(1rho)) and off-resonance T(1rho) (T(1rho)(off)) measurements to indicate acute cerebral ischemia in a rat model of transient middle cerebral artery (MCA) occlusion was investigated at 4.7 T. T(1rho) was determined with B(1) fields of 0.4, 0.8, and 1.6 G, and T(1rho)(off) with five offset frequencies ((Delta)omega) ranging from 0-7.5 kHz at B(1) of 0.4 G, yielding effective B(1) (B(eff)) from 0.4 to 1.8 G. Diffusion, T(1), and T(2) were also quantified. Both T(1rho) and T(1rho)(off) acquired with (Delta)(o)< 2.5 kHz showed positive contrast during the first hours of MCA occlusion in the ischemic tissue delineated by low diffusion. Interestingly, T(1rho)(off) contrast acquired with (Delta)omega > 2.5 kHz was clearly less sensitive to ischemic alterations, and developed with a delayed time course. This discrepancy is thought to be a consequence of the frequency dependency of cross-relaxation during irradiation with spin-lock pulses.

摘要

在4.7 T磁场下,研究了共振T(1ρ)(T(1ρ))和非共振T(1ρ)(T(1ρ)(off))测量在短暂性大脑中动脉(MCA)闭塞大鼠模型中指示急性脑缺血的能力。使用0.4、0.8和1.6 G的B(1)场测定T(1ρ),并在0.4 G的B(1)场下使用五个范围从0 - 7.5 kHz的偏移频率((Δ)ω)测定T(1ρ)(off),从而产生0.4至1.8 G的有效B(1)(B(eff))。还对扩散、T(1)和T(2)进行了量化。在低扩散描绘的缺血组织中,MCA闭塞的最初几个小时内,(Δ)o < 2.5 kHz时获得的T(1ρ)和T(1ρ)(off)均显示出阳性对比。有趣的是,(Δ)ω > 2.5 kHz时获得的T(1ρ)(off)对比对缺血改变明显不敏感,且发展过程具有延迟性。这种差异被认为是自旋锁定脉冲照射期间交叉弛豫频率依赖性的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验