[Three-dimensional finite element stress analysis of supporting bone of mandibular posterior fixed bridge. Part III. Comparative analysis with stress of the cortical bone beneath different pontics of fixed bridge].

作者信息

Tang L, Chen G

机构信息

Department of Stomatology, Medical College, Jinan University.

出版信息

Hua Xi Kou Qiang Yi Xue Za Zhi. 2000 Feb;18(1):58-60.

PMID:12539367
Abstract

OBJECTIVE

To analysis stress of the cortical bone beneath different pontics of mandibular posterior fixed bridge by using three-dimentional finite element method.

METHODS

According to the measured data, the characters of all components of fixed bridge and the supporting tissues, and the principals of finite element, the three-dimentional finite element model was developed on the basis of an adult mandible. The model consisted of 1363 nodes and 1134 elements after the fixed bridge was placed. Three different pontics were designed. Young's mudulus and Poisson's ratio were obtained from the literature for each type of tissue or materials in the model. The surfaces of pontic next to the mucosa beneath the pontic consisted of nine elements and the contact area were respectively reduced 1/3. It was assumed all materials in the model were homogeneous, isotropic and linearly elastic. One vertical load of 20 kg and one horizontal load of 20 kg were applied respectively on the occlusal surface of the abutments and the pontics of three different fixed bridge. Three-dimentional finite element stress analysis was used to calculate the epsilon max and the epsilon min of the cortical bone beneath pontics of fixed bridge.

RESULTS

Under the vertical loading, the cortical bone beneath the pontics appeared compressive stresses, the stress values of the cortical bone beneath the pontics were respectively -0.211(-)-0.119 (epsilon max, kg/mm2), -0.355(-)-0.201 (epsilon min), -0.224(-)-0.125 (epsilon max), -0.375(-)-0.215 (epsilon min), -0.239(-)-0.133 (epsilon max), -0.395(-)-0.228 (epsilon min). Under the horizontal loading, the cortical bone beneath the pontics exhibited tensile stresses and compressive stresses. The stress values of the cortical bone beneath the pontics were respectively -0.004-0.283 (epsilon max, kg/mm2), -0.249(-)-0.009 (epsilon min), -0.0042-0.301 (epsilon max), -0.264(-)-0.0095 (epsilon min), -0.0045-0.322 (epsilon max), -0.281(-)-0.0101 (epsilon min). The stress in the cortical bone beneath the pontics increased when the area of contact was reduced, the stress values changed in 5%-7%, but the rules of stress distribution of three different pontics were similar.

CONCLUSION

Stress values in the cortical bone beneath three pontics are small, and the change of stress in the cortical bone beneath the different pontics of mandibular posterior fixed bridge is small too.

摘要

相似文献

1
[Three-dimensional finite element stress analysis of supporting bone of mandibular posterior fixed bridge. Part III. Comparative analysis with stress of the cortical bone beneath different pontics of fixed bridge].
Hua Xi Kou Qiang Yi Xue Za Zhi. 2000 Feb;18(1):58-60.
2
[Three-dimensional finite element analysis of stress in supporting bone of mandibular posterior fixed bridge. II. Stress distribution of the cortical bone beneath pontic of fixed bridge].[下颌后牙固定桥支持骨应力的三维有限元分析。II. 固定桥桥体下方皮质骨的应力分布]
Hua Xi Kou Qiang Yi Xue Za Zhi. 1999 Nov;17(4):374-6.
3
[Three-dimensional finite element analysis of stress in supporting bone of mandibular posterior fixed bridge. I. Stress analysis of the surface of alveolar bone around bridge abutments].[下颌后牙固定桥支持骨应力的三维有限元分析。I. 桥基牙周围牙槽骨表面的应力分析]
Hua Xi Kou Qiang Yi Xue Za Zhi. 1999 Nov;17(4):371-3.
4
[3-dimensional finite element stress analysis of the periodontal ligament of bridge abutments in mandibular posterior fixed bridge].下颌后牙固定桥桥基牙周膜的三维有限元应力分析
Zhonghua Kou Qiang Yi Xue Za Zhi. 1993 Sep;28(5):261-4, 318.
5
[A three-dimensional finite element analysis of stress distribution in mandibular FPDs with different length pontics].[不同长度桥体的下颌固定局部义齿应力分布的三维有限元分析]
Zhonghua Kou Qiang Yi Xue Za Zhi. 2004 Mar;39(2):133-5.
6
[Three dimensional finite element stress analysis on superstructure of the fixed bridge supported by tooth-implant].牙种植体支持式固定桥上部结构的三维有限元应力分析
Zhonghua Kou Qiang Yi Xue Za Zhi. 2003 Nov;38(6):414-6.
7
Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis.牙种植体支持的固定局部义齿中,夹板固定牙数量和连接体类型变化时的生物力学相互作用:有限元分析
Clin Oral Implants Res. 2008 Jan;19(1):107-17. doi: 10.1111/j.1600-0501.2007.01363.x. Epub 2007 Oct 16.
8
Nonlinear finite element analysis of a splinted implant with various connectors and occlusal forces.具有不同连接件和咬合力的夹板式种植体的非线性有限元分析
Int J Oral Maxillofac Implants. 2003 May-Jun;18(3):331-40.
9
Fiber-reinforced composite inlay fixed partial dentures: the influence of restorative materials and abutment design on stress distribution investigated by finite element model.纤维增强复合嵌体固定局部义齿:通过有限元模型研究修复材料和基牙设计对应力分布的影响。
Minerva Stomatol. 2009 Oct;58(10):459-70.
10
Finite element analysis of a three unit fixed partial denture cast with nickel-chromium alloy.
Indian J Dent Res. 1999 Jan-Mar;10(1):11-4.