Abstract

BACKGROUND AND PURPOSE

Physical therapists routinely observe gait in clinical practice. The purpose of this study was to determine the accuracy and reliability of observational assessments of push-off in gait after stroke.

SUBJECTS

Eighteen physical therapists and 11 subjects with hemiplegia following a stroke participated in the study.

METHODS

Measurements of ankle power generation were obtained from subjects following stroke using a gait analysis system. Concurrent videotaped gait performances were observed by the physical therapists on 2 occasions. Ankle power generation at push-off was scored as either normal or abnormal using two 11-point rating scales. These observational ratings were correlated with the measurements of peak ankle power generation.

RESULTS

A high correlation was obtained between the observational ratings and the measurements of ankle power generation (mean Pearson r=.84). Interobserver reliability was moderately high (mean intraclass correlation coefficient [ICC (2,1)]=.76). Intraobserver reliability also was high, with a mean ICC (2,1) of.89 obtained.

DISCUSSION AND CONCLUSION

Physical therapists were able to make accurate and reliable judgments of push-off in videotaped gait of subjects following stroke using observational assessment. Further research is indicated to explore the accuracy and reliability of data obtained with observational gait analysis as it occurs in clinical practice.

摘要

背景与目的

物理治疗师在临床实践中经常观察步态。本研究的目的是确定中风后步态蹬离期观察性评估的准确性和可靠性。

受试者

18名物理治疗师和11名中风后偏瘫患者参与了本研究。

方法

使用步态分析系统获取中风患者的踝关节发力测量值。物理治疗师在两个场合对同步录制的步态表现进行观察。使用两个11分制评分量表将蹬离期的踝关节发力评为正常或异常。这些观察评分与踝关节最大发力测量值相关。

结果

观察评分与踝关节发力测量值之间具有高度相关性(平均皮尔逊相关系数r = 0.84)。观察者间信度中等偏高(平均组内相关系数[ICC(2,1)] = 0.76)。观察者内信度也很高,平均ICC(2,1)为0.89。

讨论与结论

物理治疗师能够通过观察性评估对中风患者录像步态中的蹬离期做出准确可靠的判断。有必要进行进一步研究,以探索在临床实践中进行观察性步态分析所获得数据的准确性和可靠性。