Suppr超能文献

CT和MR血管造影中的对比剂增强峰值:何时出现及原因?猪模型的药代动力学研究。

Peak contrast enhancement in CT and MR angiography: when does it occur and why? Pharmacokinetic study in a porcine model.

作者信息

Bae Kyongtae T

机构信息

Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110, USA.

出版信息

Radiology. 2003 Jun;227(3):809-16. doi: 10.1148/radiol.2273020102. Epub 2003 Apr 17.

Abstract

PURPOSE

To investigate pharmacokinetic and physiologic factors that determine the time to peak intravenous contrast medium enhancement in computed tomographic (CT) and magnetic resonance (MR) angiography in the porcine mid-abdominal aorta.

MATERIALS AND METHODS

Four pigs were imaged repeatedly in seven to eight sets: For each set, 20 dynamic CT scans were obtained at a fixed aortic level after intravenous injection of contrast medium. From a physiologically based compartment model, aortic contrast enhancement curves were generated by varying contrast medium injection duration from 1 to 40 seconds. Contrast enhancement curves and times to peak aortic enhancement from the experiment and model were compared. Time to peak aortic enhancement obtained from the injection with the shortest duration was considered the time to peak test bolus contrast enhancement. Mathematic and pharmacokinetic analyses were performed to investigate factors that determine peak enhancement.

RESULTS

Empiric and compartmental model times to peak aortic enhancement were in good agreement. Time to peak aortic enhancement corresponded to the weighted sum of injection duration and time to peak test bolus enhancement. With increasing injection duration, the relative contribution of injection duration to peak aortic enhancement time increased. When injection duration was longer than time to peak test bolus enhancement, time to peak aortic enhancement increased linearly with injection duration and occurred shortly after completion of injection. However, when injection duration was shorter than time to peak test bolus enhancement, time to peak aortic enhancement was determined predominantly by time to peak test bolus enhancement and only gradually increased with injection duration.

CONCLUSION

Time to peak aortic enhancement is determined by the relative contributions of injection duration and contrast medium traveling time and may well be explained by contrast medium volumetric inflow and recirculation physiology.

摘要

目的

研究在猪腹主动脉中部的计算机断层扫描(CT)和磁共振(MR)血管造影中,决定静脉注射造影剂达到峰值增强时间的药代动力学和生理学因素。

材料与方法

对4头猪进行7至8组重复成像:每组在静脉注射造影剂后,于固定的主动脉水平获取20次动态CT扫描。基于生理的房室模型,通过将造影剂注射持续时间从1秒变化到40秒,生成主动脉造影剂增强曲线。比较实验和模型得到的造影剂增强曲线及主动脉增强峰值时间。将最短注射持续时间注射得到的主动脉增强峰值时间视为测试团注造影剂增强峰值时间。进行数学和药代动力学分析以研究决定峰值增强的因素。

结果

经验性和房室模型的主动脉增强峰值时间吻合良好。主动脉增强峰值时间与注射持续时间和测试团注增强峰值时间的加权和相对应。随着注射持续时间增加,注射持续时间对主动脉增强峰值时间的相对贡献增加。当注射持续时间长于测试团注增强峰值时间时,主动脉增强峰值时间随注射持续时间呈线性增加,并在注射完成后不久出现。然而,当注射持续时间短于测试团注增强峰值时间时,主动脉增强峰值时间主要由测试团注增强峰值时间决定,仅随注射持续时间逐渐增加。

结论

主动脉增强峰值时间由注射持续时间和造影剂运行时间的相对贡献决定,并且很可能由造影剂体积流入和再循环生理学来解释。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验