Abu-Zreig Majed, Rudra Ramesh P, Whiteley Hugh R, Lalonde Manon N, Kaushik Narinder K
Dep. of Biosystems Engineering, Jordan Univ. of Science and Technology, P.O. Box 3030, Irbid, Jordan.
J Environ Qual. 2003 Mar-Apr;32(2):613-9. doi: 10.2134/jeq2003.6130.
Vegetated filter strips (VFS) are used recently for removal, at or near the source, of sediment and sediment-bound chemicals from cropland runoff. Vegetation within the flowpath increases water infiltration and decreases water turbulence, thus enhancing pollutant removal by sedimentation within filter media and infiltration through the filter surface. Field experiments have been conducted to examine the efficiency of vegetated filter strips for phosphorus removal from cropland runoff with 20 filters with varying length (2 to 15 m), slope (2.3 and 5%), and vegetated cover, including bare-soil plots as control. Artificial runoff used in this study had an average phosphorus concentration of 2.37 mg L(-1) and a sediment concentration of 2700 mg L(-1). The average phosphorus trapping efficiency of all vegetated filters was 61% and ranged from 31% in a 2-m filter to 89% in a 15-m filter. Filter length has been found to be the predominant factor affecting P trapping in VFS. The rate of inflow, type of vegetation, and density of vegetation coverage had secondary influences on P removal. Short filters (2 and 5 m), which are somewhat effective in sediment removal, are much less effective in P removal. Increasing the filter length beyond 15 m is ineffective in enhancing sediment removal but is expected to further enhance P removal. Sediment deposition, infiltration, and plant adsorption are the primary mechanisms for phosphorus trapping in VFS.
植被过滤带(VFS)最近被用于在源头或源头附近去除农田径流中的沉积物及与沉积物结合的化学物质。水流路径中的植被增加了水分入渗并降低了水流紊动,从而通过过滤介质内的沉淀作用以及通过过滤表面的入渗作用提高了污染物去除效率。已开展田间试验,以研究植被过滤带对农田径流中磷的去除效率,试验设置了20个过滤带,其长度(2至15米)、坡度(2.3%和5%)以及植被覆盖情况各不相同,包括裸土地块作为对照。本研究中使用的人工径流平均磷浓度为2.37毫克/升,沉积物浓度为2700毫克/升。所有植被过滤带的平均磷截留效率为61%,范围从2米过滤带的31%到15米过滤带的89%。已发现过滤带长度是影响植被过滤带中磷截留的主要因素。流入速率、植被类型和植被覆盖密度对磷去除有次要影响。较短的过滤带(2米和5米)在去除沉积物方面有一定效果,但在去除磷方面效果要差得多。将过滤带长度增加到15米以上对增强沉积物去除效果无效,但预计会进一步提高磷去除效果。沉积物沉积、入渗和植物吸附是植被过滤带中磷截留的主要机制。