Suppr超能文献

[多层螺旋CT冠状动脉成像:采用多段重建和可变机架旋转时间优化图像质量]

[Imaging of the coronary arteries by means of multislice helical CT: optimization of image quality with multisegmental reconstruction and variable gantry rotation time].

作者信息

Lembcke A, Rogalla P, Mews J, Blobel J, Enzweiler C N, Wiese T H, Hermann K-G A, Hamm B

机构信息

Institut für Radiologie, Universitätsklinikum Charité, Campus Charité Mitte, Humboldt-Universität zu Berlin.

出版信息

Rofo. 2003 Jun;175(6):780-5. doi: 10.1055/s-2003-39932.

Abstract

PURPOSE

To evaluate the potential of multisegmental reconstruction and variable gantry rotation time for reducing motion-induced artifacts in coronary artery imaging by multislice helical CT.

MATERIALS AND METHODS

The data sets of 20 patients (8 with HR < 60 bpm, 12 with HR > 60 bpm) were analyzed. The patients underwent multislice helical CT (Aquilion 8, Toshiba, Otawara, Japan) using the following parameters: 0.5 mm slice thickness, 250 mA, 120 kV, pitch of 0.25 and variable gantry rotation times of 400, 500, or 600 msec. Images were generated by halfscan and multisegmental reconstruction. In 9 coronary segments of each patient, the presence and severity of motion artifacts were assessed and graded on a scale between 5 (no artifacts) and 1 (heaviest artifacts).

RESULTS

Diagnostically relevant motion artifacts were rare at low heart rates (< 60 bpm) for both types of image reconstruction (4 % of all segments). Higher heart rates (> 60 bpm) were associated with an increase in motion artifacts on halfscan reconstructions (33% of all segments, p < 0.05) but not on multisegmental reconstructions (4% of all segments). At low heart rates mean image quality did not differ between multisegmental and halfscan reconstruction (4.28 +/- 0.37 vs. 4.22 +/- 0.41; p > 0.05), whereas at higher heart rates image quality was better for multisegmental reconstruction than for halfscan reconstruction (4.23 +/- 0.47 vs. 3.11 +/- 0.63; p < 0.05).

CONCLUSION

Multisegmental reconstruction with variable gantry rotation times suppresses motion artifacts and thus improves assessment of the coronary arteries in patients with higher heart rates.

摘要

目的

评估多层螺旋CT冠状动脉成像中多段重建及可变机架旋转时间减少运动伪影的潜力。

材料与方法

分析20例患者(8例心率<60次/分,12例心率>60次/分)的数据集。患者接受多层螺旋CT(日本大田原东芝Aquilion 8)检查,采用以下参数:层厚0.5mm,管电流250mA,管电压120kV,螺距0.25,机架旋转时间分别为400、500或600毫秒。图像通过半扫描和多段重建生成。在每位患者的9个冠状动脉节段中,评估运动伪影的存在及严重程度,并按5分(无伪影)至1分(最重伪影)进行分级。

结果

对于两种图像重建方式,低心率(<60次/分)时诊断相关的运动伪影很少见(占所有节段的4%)。高心率(>60次/分)时,半扫描重建的运动伪影增多(占所有节段的33%,p< 0.05),而多段重建时运动伪影无明显增加(占所有节段的4%)。低心率时,多段重建和半扫描重建的平均图像质量无差异(4.28±0.37对4.22±0.41;p>0.05),而高心率时,多段重建的图像质量优于半扫描重建(4.23±0.47对3.11±0.63;p<0.05)。

结论

可变机架旋转时间的多段重建可抑制运动伪影,从而改善高心率患者冠状动脉的评估。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验