Short-term load bearing capacity of osteochondral autografts implanted by the mosaicplasty technique: an in vitro porcine model.

作者信息

Whiteside R A, Bryant J T, Jakob R P, Mainil-Varlet P, Wyss U P

机构信息

Department of Mechanical Engineering, Queen's University, Kingston, Ontario, Canada K7L 3N6.

出版信息

J Biomech. 2003 Aug;36(8):1203-8. doi: 10.1016/s0021-9290(03)00115-5.

Abstract

Articular surface congruency and graft stability are considered essential factors in the success of osteochondral grafting; however, quantitative measures of short-term load bearing capacity of grafts implanted by the mosaicplasty technique have not been reported. The purpose of this study was to develop a live tissue in vitro model to examine short-term fixation strength of mosaicplasty autografts immediately after and 1 week following graft implantation. Cylindrical osteochondral autografts were implanted in vitro by the mosaicplasty technique on five pairs of porcine femoral condyles within one and a half hours of animal sacrifice. Immediately following the surgical procedure, graft push-in and pull-out strength tests as well as indentation tests to determine modulus of the surrounding cancellous bone were performed on half of the specimens from the distal femurs of each animal. The remaining specimens, matched for location in the contralateral leg, were incubated in culture medium for 7 days prior to performing the same set of mechanical tests. Averaged push-in and pull-out graft fixation strength decreased 44% from 135.7 to 75.5N over the 7-day period, while no change in modulus was detected in the surrounding cancellous bone. These in vitro results demonstrate a substantial deterioration of short-term fixation strength of mosaicplasty grafts from the immediate post-operative state. Such a reduction in short-term graft load bearing capacity may pose a threat to the surgically established articular surface congruency and blood vessels formed during the early stages of the healing response.

摘要

关节面的一致性和移植物稳定性被认为是骨软骨移植成功的关键因素;然而,关于采用镶嵌成形术植入的移植物短期承重能力的定量测量尚未见报道。本研究的目的是建立一个活组织体外模型,以检测镶嵌成形术自体移植物在植入后即刻以及植入后1周时的短期固定强度。在动物处死后的一个半小时内,通过镶嵌成形术将圆柱形骨软骨自体移植物体外植入五对猪股骨髁。手术操作后,立即对每只动物股骨远端一半的标本进行移植物压入和拔出强度测试以及压痕测试,以确定周围松质骨的模量。将对侧腿部位置匹配的其余标本在培养基中孵育7天,然后进行相同的一组力学测试。在7天的时间里,平均压入和拔出移植物固定强度从135.7N下降到75.5N,下降了44%,而周围松质骨的模量未检测到变化。这些体外结果表明,镶嵌成形术移植物的短期固定强度从术后即刻状态开始显著下降。这种短期移植物承重能力的降低可能对手术建立的关节面一致性以及愈合反应早期形成的血管构成威胁。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验