Suppr超能文献

用手指动脉脉搏波幅度评估外周血管内皮功能。

Assessment of peripheral vascular endothelial function with finger arterial pulse wave amplitude.

作者信息

Kuvin Jeffrey T, Patel Ayan R, Sliney Kathleen A, Pandian Natesa G, Sheffy Jacob, Schnall Robert P, Karas Richard H, Udelson James E

机构信息

Department of Medicine, Division of Cardiology, Tufts-New England Medical Center Hospitals, Tufts University School of Medicine, Boston, MA 02111, USA.

出版信息

Am Heart J. 2003 Jul;146(1):168-74. doi: 10.1016/S0002-8703(03)00094-2.

Abstract

BACKGROUND

Abnormalities in pulse wave amplitude (PWA) have been described in subjects with atherosclerosis and may be a marker of future cardiac events. We evaluated the relationship between changes in PWA of the finger and peripheral endothelial function.

METHODS

We performed measurements of PWA with a novel finger plethysmograph (peripheral arterial tonometry [PAT]) and compared the findings with a simultaneous noninvasive measurement of peripheral endothelial function with brachial artery ultrasound scanning (BAUS) in 89 subjects. The PAT hyperemia ratio was defined as the ratio of PWA during reactive hyperemia relative to the baseline. Flow-mediated dilation (FMD) was defined by BAUS as the ratio of the brachial artery diameter during reactive hyperemia relative to the baseline. Sixty-eight subjects underwent exercise myocardial perfusion imaging (ExMPI).

RESULTS

Fifty-four men and 35 women were examined. There was a linear relationship between the PAT hyperemia ratio and FMD during the same episode of reactive hyperemia (r = 0.55, P <.0001). Subjects in the lowest FMD quartile had the lowest PAT hyperemia ratio, whereas subjects in the highest FMD quartile had the highest PAT hyperemia ratio (P <.001 for trend). Similar to BAUS, the PAT hyperemia ratio was more impaired in subjects with cardiovascular risk factors and in subjects with ExMPI studies that were indicative of coronary artery disease.

CONCLUSIONS

Assessment of PWA with PAT demonstrates patterns of abnormality similar to that of BAUS assessment of FMD. PWA during reactive hyperemia is influenced by factors known to affect endothelial function, including cardiovascular risk factors and coronary artery disease. These findings support the concept that analysis of PWA with PAT during reactive hyperemia may be used to study peripheral vascular endothelial function.

摘要

背景

动脉粥样硬化患者存在脉搏波振幅(PWA)异常,这可能是未来心脏事件的一个标志物。我们评估了手指PWA变化与外周内皮功能之间的关系。

方法

我们使用一种新型手指体积描记仪(外周动脉张力测定法[PAT])测量PWA,并将结果与89名受试者同时使用肱动脉超声扫描(BAUS)进行的外周内皮功能无创测量结果进行比较。PAT充血率定义为反应性充血期间PWA与基线的比值。BAUS将血流介导的血管舒张(FMD)定义为反应性充血期间肱动脉直径与基线的比值。68名受试者接受了运动心肌灌注成像(ExMPI)检查。

结果

共检查了54名男性和35名女性。在同一反应性充血过程中,PAT充血率与FMD之间存在线性关系(r = 0.55,P <.0001)。FMD处于最低四分位数的受试者PAT充血率最低,而FMD处于最高四分位数的受试者PAT充血率最高(趋势P <.001)。与BAUS相似,PAT充血率在有心血管危险因素的受试者以及ExMPI研究提示有冠状动脉疾病的受试者中受损更明显。

结论

用PAT评估PWA显示出与BAUS评估FMD相似的异常模式。反应性充血期间的PWA受已知影响内皮功能的因素影响,包括心血管危险因素和冠状动脉疾病。这些发现支持这样一种观点,即反应性充血期间用PAT分析PWA可用于研究外周血管内皮功能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验