• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Transesophageal atrial stimulation: a technic with the pentapolar catheter electrode].

作者信息

Seminario Origgi M A, Alves de Godoy R

机构信息

Departamento de Clínica Médica, Facultad de Medicina de Ribeirão Preto, Universidad de São Paulo, Brasil.

出版信息

Arch Inst Cardiol Mex. 1992 Nov-Dec;62(6):547-55.

PMID:1285665
Abstract

The objective of the present study was to employ a transesophageal atrial pacing (TAP) technique that would permit the use of the lowest possible currents for consistent atrial capture (CAC) and a more accurate recording system. An electrode catheter containing five poles (E1 to E5) spaced 22 mm apart was constructed, with pole E1 being the most cranial one. The catheter was introduced nasally into the esophagus of eleven adult healthy volunteers, and five unipolar intraesophageal leads were recorded and analyzed until the tracings obtained with E2, E3 and E4 showed P waves of the highest potentials, when the catheter was fixed in place. An electric generator specially constructed for TAP was used. CAC was attempted with each of the 20 stimulating bipoles formed by the permutations of the five poles of the fixed catheter. The least voltage needed for CAC in each individual was always detected in at least one of the six stimulating bipoles formed by the permutations involving poles E2, E3 and E4. Thus, in the population studied as a whole, the minimum voltage range needed to obtain TAP was between 5 and 15 V (mean 11.2 +/- 3.0 V), which was tolerated quite well by the individuals. Pulse durations of more than 10 ms did not lead to use of significantly lower voltages for CAC. Six simultaneous tracings were used during and after TAP, and at least one of them recorded intraesophageal or esophago-thoracic bipolar leads.

摘要

相似文献

1
[Transesophageal atrial stimulation: a technic with the pentapolar catheter electrode].
Arch Inst Cardiol Mex. 1992 Nov-Dec;62(6):547-55.
2
[Transesophageal atrial stimulation].经食管心房刺激
Arch Inst Cardiol Mex. 1990 May-Jun;60(3):241-51.
3
Balloon electrode catheter for transesophageal atrial pacing and transesophageal ECG recording.
Pacing Clin Electrophysiol. 1992 Nov;15(11 Pt 2):1953-6. doi: 10.1111/j.1540-8159.1992.tb03000.x.
4
Utility of transesophageal electrocardiography to guide optimal placement of a transesophageal pacing catheter in dogs.
Vet Anaesth Analg. 2015 Jan;42(1):99-102. doi: 10.1111/vaa.12164. Epub 2014 Apr 16.
5
[Transesophageal electrophysiological study. A report of 2 cases].[经食管电生理研究。2例报告]
Arch Inst Cardiol Mex. 1993 May-Jun;63(3):253-7.
6
First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices.经皮超声能量传输实现心脏刺激的首例人体演示:对植入式设备无线起搏的启示。
J Am Coll Cardiol. 2007 Aug 28;50(9):877-83. doi: 10.1016/j.jacc.2007.04.081. Epub 2007 Aug 13.
7
[Transesophageal atrial stimulation--a test for myocardial ischemia].[经食管心房刺激——一种心肌缺血检测方法]
Lijec Vjesn. 1994 Jan-Feb;116(1-2):35-40.
8
Transesophageal atrial pacing--stimulation and discomfort thresholds: the role of electrode configuration and pulse width.
Pacing Clin Electrophysiol. 1991 Sep;14(9):1359-66. doi: 10.1111/j.1540-8159.1991.tb02881.x.
9
[Electrode-myocardium distance in transesophageal atrial stimulation].经食管心房刺激时电极与心肌的距离
Z Gesamte Inn Med. 1990 Nov 1;45(21):643-6.
10
Performance evaluation of a right atrial automatic capture verification algorithm using two different sensing configurations.使用两种不同传感配置对右心房自动捕获验证算法的性能评估。
Pacing Clin Electrophysiol. 2009 May;32(5):579-87. doi: 10.1111/j.1540-8159.2009.02330.x.