Singh A, Letsky E A, Stark J
J Thorac Cardiovasc Surg. 1976 Feb;71(2):226-9.
A 41/2-year-old child developed a severe degree of intravascular hemolysis within 24 hours after intraventricular correction of double-outlet right ventricle with a Dacron patch. The child developed jaundice, with a serum bilirubin of 4.3 mg. per cent. The hematocrit value fell from 47 to 25 per cent and the reticulocyte count rose to 22 per cent. The hemolysis diminished after 3 weeks and completely disappeared after 6 weeks. We presume that the hemolysis was due to turbulence caused by a long, curved patch and that its disappearance coincided with the endothelialization of the patch. The child is well 3 years after the operation.
一名4岁半的儿童在采用涤纶补片进行右心室双出口心室内心脏矫正术后24小时内出现了严重程度的血管内溶血。该儿童出现黄疸,血清胆红素为4.3毫克/百分比。血细胞比容值从47%降至25%,网织红细胞计数升至22%。溶血在3周后减轻,6周后完全消失。我们推测溶血是由长而弯曲的补片引起的血流紊乱所致,其消失与补片的内皮化同时发生。该儿童术后3年情况良好。