Sivakumaran Soori, Krahn Andrew D, Klein George J, Finan Jane, Yee Raymond, Renner Suzanne, Skanes Allan C
Division of Cardiology, University of Western Ontario, London, Ontario, Canada.
Am J Med. 2003 Jul;115(1):1-5. doi: 10.1016/s0002-9343(03)00233-x.
The initial management of syncope or presyncope typically involves short-term cardiac monitoring using a Holter monitor. A loop recorder is used to extend the period of monitoring to increase the probability of obtaining a symptom-rhythm correlation. Loop recorders and Holter monitors are both used commonly, but their utility has not been compared prospectively.
Patients with syncope or presyncope referred for a Holter monitor or a loop recorder were assigned randomly to receive either a 48-hour Holter monitor or a loop recorder for 1 month as an initial diagnostic strategy. If the initial strategy was unsuccessful, patients were offered crossover to the alternate strategy.
One hundred patients (mean [+/- SD] age, 56 +/- 20 years; 44 women) with syncope (n = 21), presyncope (n = 29), or both (n = 50) were enrolled. Of the 49 patients assigned randomly to an external loop recorder first, 31 (63%) had an arrhythmia identified or excluded, versus 12 (24%) of 51 patients assigned to a Holter monitor initially (P <0.0001). Arrhythmia was identified as a cause of syncope in 1 patient with a loop recorder, compared with no patients with a Holter monitor (P = 0.31). Of the 29 patients with negative results with Holter monitoring who went on to receive a loop recorder, 13 (45%) had arrhythmia excluded, compared with none of the 4 patients who crossed over to receive a Holter monitor. The overall probability of obtaining a symptom-rhythm correlation was 56% (44/78) for loop recorders versus 22% (12/55) for Holter monitors (P <0.0001). Despite patient education and test transmissions, 13 (23%) of 57 patients who had recurrence of their symptoms failed to activate their loop recorder properly.
Loop recorders have a much higher diagnostic yield for patients with syncope or presyncope as compared with Holter monitors. The utility of loop recorders is limited by some patients' inability to operate them correctly.