Pupka Artur, Skóra Jan, Janczak Dariusz, Ruciński Artur, Korta Krzysztof, Barć Piotr, Stepiński Piotr, Szyber Piotr
Department of Vascular, General and Transplantological, Wrocław Medical University.
Polim Med. 2003;33(1-2):41-5.
In this paper the use of silver-coated medical prosthesis of massive aorto-bifemoral and ilio-femoral dacron graft infection with hemorrhage is presented. To solve this problem in situ replacement was attempted using silver-coated dacron vascular prosthesis more resistant to infection. 9 patients with this therapeutic method is reported. Although positive clinical effect was obtained, the scintigraphy and Duplex Doppler Ultrasound of implanted graft revealed its infection. In our opinion therefore application of silver-coated medical prosthesis should be very cautious and limited to the critical states.
本文介绍了使用镀银医用假体治疗大面积主-双股和髂-股涤纶人工血管感染并出血的情况。为解决这一问题,尝试使用更具抗感染能力的镀银涤纶血管假体进行原位置换。报告了9例采用该治疗方法的患者。尽管取得了积极的临床效果,但对植入人工血管的闪烁扫描和双功能多普勒超声检查显示仍存在感染。因此,我们认为镀银医用假体的应用应非常谨慎,仅限于危急情况。