高效液相色谱-安培检测法测定多组分镇痛制剂中的4-氨基苯酚杂质

Determination of 4-aminophenol impurities in multicomponent analgesic preparations by HPLC with amperometric detection.

作者信息

Wyszecka-Kaszuba E, Warowna-Grześkiewicz M, Fijałek Z

机构信息

Department of Pharmaceutical Chemistry, Drug Institute, National Institute of Public Health, 30/34 Chełmska Str., 00-725 Warsaw, Poland.

出版信息

J Pharm Biomed Anal. 2003 Aug 8;32(4-5):1081-6. doi: 10.1016/s0731-7085(03)00212-7.

Abstract

A method for the determination of 4-aminophenol, the main impurity of paracetamol, by high-performance liquid chromatographic (HPLC) method with amperometric detection has been developed. The analysis was performed in an isocratic mode on a reversed phase Luna column 5 microm C-18 (100 x 4.6 mm). A mobile phase (0.05 mol l(-1) LiCl solution containing 18% methanol adjusted to pH 4.0 with orthophosphoric acid) was suitable for the separation and determination of 4-APh. Chromatograms were recorded for 250 s by means of an amperometric detector at a potential of +325 mV of the glassy carbon electrode versus the reference electrode Ag/AgCl. The proposed liquid chromatographic method was successfully applied to the analysis of commercially available multicomponent dosage forms. The sensitivity of the detection for 4-aminophenol was 1 ng ml(-1) for substance and 4 ng ml(-1) for tablets or capsules. The method developed in this study is sensitive and selective and can be applied for routine studies of pharmaceuticals in the form of tablets or capsules.

摘要

已开发出一种采用高效液相色谱(HPLC)安培检测法测定对乙酰氨基酚主要杂质4-氨基酚的方法。分析在反相Luna柱5微米C-18(100×4.6毫米)上以等度模式进行。流动相(含18%甲醇的0.05 mol l(-1) LiCl溶液,用正磷酸调至pH 4.0)适用于4-氨基酚的分离和测定。通过安培检测器在玻碳电极相对于参比电极Ag/AgCl的+325 mV电位下记录250秒的色谱图。所提出的液相色谱法成功应用于市售多组分剂型的分析。4-氨基酚的检测灵敏度对于原料药为1 ng ml(-1),对于片剂或胶囊为4 ng ml(-1)。本研究中开发的方法灵敏且具有选择性,可应用于片剂或胶囊形式药物的常规研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验