Pinto Nelangi, Jones Thomas K, Dyamenahalli Umesh, Shah Maully J
Department of Pediatrics, University of Washington, Seattle, Washington 98112, USA.
Pacing Clin Electrophysiol. 2003 Jul;26(7 Pt 1):1519-22. doi: 10.1046/j.1460-9592.2003.t01-1-00220.x.
Various techniques and electrode catheters have been developed for effective and safe temporary transvenous cardiac pacing. In neonates and children, lead dislodgment and myocardial perforation have been attendant risks with passive fixation leads. We report our experience with the recently introduced Medtronic 6416 active fixation bipolar lead in a small group of children. Between January 2000 and February 2002, 4 children (2 boys, 2 girls) underwent temporary transvenous pacing with the Medtronic 6416 lead. The median age at implantation was 4.25 years (range: 5 days-13 years), median weight was 14.5 kg (range: 2.5 kg-54 kg) and the median duration of temporary pacing was 19.5 days (range: 5-38 days). The indication for temporary pacing was AV block (n = 2), sinus arrest (n = 1) and sinus node dysfunction (n = 1). The acute pacing threshold was <1.5 mA with no significant rise in the follow-up period. The venous access for lead placement was femoral vein (n = 2), internal jugular vein (n = 1), and subclavian vein (n = 1). There were no complications related to implantation or in the follow-up period. The Medtronic 6416 lead appears to be a safe and effective tool in temporary transvenous pacing in neonates and children.
为实现有效且安全的临时经静脉心脏起搏,已研发出多种技术和电极导管。在新生儿和儿童中,被动固定电极导线存在导线移位和心肌穿孔的风险。我们报告了在一小群儿童中使用最近推出的美敦力6416主动固定双极电极导线的经验。2000年1月至2002年2月期间,4名儿童(2名男孩,2名女孩)使用美敦力6416电极导线进行了临时经静脉起搏。植入时的中位年龄为4.25岁(范围:5天至13岁),中位体重为14.5千克(范围:2.5千克至54千克),临时起搏的中位持续时间为19.5天(范围:5至38天)。临时起搏的指征为房室传导阻滞(n = 2)、窦性停搏(n = 1)和窦房结功能障碍(n = 1)。急性起搏阈值<1.5毫安,随访期间无显著升高。导线置入的静脉通路为股静脉(n = 2)、颈内静脉(n = 1)和锁骨下静脉(n = 1)。植入或随访期间均无并发症。美敦力6416电极导线似乎是新生儿和儿童临时经静脉起搏的一种安全有效的工具。