Appl Opt. 2003 Aug 1;42(22):4541-8. doi: 10.1364/ao.42.004541.
The effect of diffraction the instrument line shape of a Fourier-transform spectrometer is studied with an analytical line-shape model. The expression for the instrument line shape of a diffracted point source is obtained. A simple condition on the throughput of the instrument is derived under which diffraction is negligible when compared with the field-of-view-induced line shape. The effect of diffraction is illustrated and compared for various instruments.
利用解析线型模型研究了衍射对傅里叶变换光谱仪仪器线型的影响。得到了衍射点源仪器线型的表达式。推导了仪器通量的一个简单条件,在该条件下,与视场诱导线型相比,衍射可忽略不计。阐述并比较了不同仪器的衍射效应。