Suppr超能文献

悬浮液进样-火焰原子吸收光谱法测定怀药中的铜、锌和铁

[Determination of Cu, Zn and Fe in Huaiyao by suspension sampling-flame atomic absorption spectrometry].

作者信息

Wei Wei, Qu Ling-bo, Li Jian-jun, Li Yan-hong

机构信息

Department of Chemistry, Zhengzhou University, Zhengzhou 450052, China.

出版信息

Guang Pu Xue Yu Guang Pu Fen Xi. 2002 Oct;22(5):856-8.

Abstract

A new method--suspension sampling technique was applied to flame atomic absorption spectrometry and was successfully used to determine Cu, Zn, Fe in Huaiyao. Then studied the choice of suspension agent and elimination of chemical interference. The huaiyao sample was suspended in agar sol, and injected into air-acetylene flame by using standard addition method to determine Cu, Zn, Fe. Determined results were consistent with those obtained by HNO3 + H2SO4 + HClO4 method. The t-test showed that no obvious difference was found between the two methods. Displacement of HNO3 + H2SO4 + HClO4 method by suspension sampling method for the sample pretreatment is possible. This method is convenient, rapid and accurate.

摘要

一种新方法——悬浮液进样技术被应用于火焰原子吸收光谱法,并成功用于测定淮药中的铜、锌、铁。然后研究了悬浮剂的选择和化学干扰的消除。将淮药样品悬浮于琼脂溶胶中,采用标准加入法注入空气-乙炔火焰中测定铜、锌、铁。测定结果与硝酸+硫酸+高氯酸法所得结果一致。t检验表明两种方法之间没有明显差异。悬浮进样法用于样品预处理以取代硝酸+硫酸+高氯酸法是可行的。该方法简便、快速、准确。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验