Chraibi S, Beghetti M, el Hattaoui M, Fadouach S, Kalangos A, Mehadji B A, Faidutti B, Friedli B, Tahiri A, Chraibi N
Unité de cardiologie pédiatrique, hôpital Cautonal de Genève, Suisse.
Ann Cardiol Angeiol (Paris). 2003 Jun;52(3):188-90. doi: 10.1016/s0003-3928(03)00058-1.
Postoperative aneurysm of ductus arteriosus is a rare complication but may be lethal without treatment. It is less frequent than spontaneous aneurysm of ductus arteriosus. We report the case of 5 years-old girl who underwent a ligation of patent ductus arteriosus complicated, 6 months later, with a false aneurysm of ductus arteriosus and endocarditis of the ductus and the aortic valve. The diagnosis of the aneurysm was suspected on the anteroposterior chest X-ray which showed a left superior mediastinal opacity and confirmed by echocardiography. Through bilateral thoracotomy, an anevrismorraphy and aortic repair was carried out without problem. The postoperative course was unremarkable.