Kohan Darius, Sorin Alexander
Department of Otolaryngology, New York University, School of Medicine, New York, New York, USA.
Laryngoscope. 2003 Sep;113(9):1520-4. doi: 10.1097/00005537-200309000-00020.
To determine the effectiveness of the malleus to oval window wire-piston revision stapes surgery technique.
A retrospective analysis of 243 stapes procedures performed by the senior author over a 10-year period identified 15 revisions. Five patients underwent a malleus to oval window wire-piston technique. All patients were followed for at least 6 months. The surgical outcome including audiologic data and complications are noted.
Stapes surgery was performed on an ambulatory basis by way of a transcanal approach under local anesthesia with monitored sedation by the same surgeon using a laser technique and a stapes wire-piston prosthesis.
Among revision stapes procedures, there was no significant difference in the air-bone gap closure or complication rate between the incus to oval window and the malleus to oval window techniques. The average preoperative air-bone gap in all revisions was 32 dB, whereas the mean postoperative gap was 10 dB hearing loss.
In experienced hands, revision stapes surgery using the malleus to oval window stapes wire-piston prosthesis is safe and effective.
确定锤骨至卵圆窗钢丝活塞式镫骨手术技术的有效性。
对资深作者在10年期间实施的243例镫骨手术进行回顾性分析,确定了15例翻修手术。5例患者接受了锤骨至卵圆窗钢丝活塞技术。所有患者均随访至少6个月。记录手术结果,包括听力学数据和并发症。
在局部麻醉和监测镇静下,由同一位外科医生通过经耳道入路在门诊进行镫骨手术,采用激光技术和镫骨钢丝活塞假体。
在镫骨翻修手术中,砧骨至卵圆窗技术与锤骨至卵圆窗技术在气骨导间距缩小或并发症发生率方面无显著差异。所有翻修手术患者术前平均气骨导间距为32dB,术后平均间距为听力损失10dB。
在经验丰富的医生手中,使用锤骨至卵圆窗镫骨钢丝活塞假体进行镫骨翻修手术是安全有效的。