Suppr超能文献

CO2 激光辅助镫骨切开术联合 àWengen 钛夹镫骨假体:优越的短期疗效。

CO2 laser-assisted stapedotomy combined with àWengen titanium clip stapes prosthesis: superior short-term results.

机构信息

Department of Otorhinolaryngology and Head and Neck Surgery, Heilig Hart General Hospital Roeselare, Roeselare, Belgium.

出版信息

Otol Neurotol. 2009 Dec;30(8):1071-8. doi: 10.1097/MAO.0b013e3181a52ab4.

Abstract

OBJECTIVE

To report on the short-term results of CO2-laser assisted stapedotomy combined with the àWengen titanium clip stapes prosthesis. A comparison with published series using other prostheses and/or different stapedotomy techniques is made.

STUDY DESIGN

Retrospective case series.

PATIENTS

Patients with a history and audiologic data matching stapes fixation and computed tomographic imaging excluding other anomalies such as malleus fixation, dehiscent superior semicircular canal, and large vestibular aqueduct that may mimic stapes fixation-like hearing loss.

INTERVENTION

All patients underwent CO2 laser-assisted stapedotomy (Lumenis Co. Israel CO2 laser, Acuspot 712, SurgiTouch 870 scanner) and subsequent reconstruction by means of the àWengen titanium clip stapes prosthesis by Heinz Kurz Medizintechnik GmbH (Germany).

OUTCOME MEASURES

Comparison and statistical analysis of preoperative and postoperative audiologic data.

RESULTS

Sixty-two stapedotomies were performed (61 patients) using the CO2 laser and àWengen titanium clip stapes prosthesis. The mean postoperative air-bone gap 3 months postoperatively was 5.1 +/- 0.5 dB (standard deviation [SD], 4.1 dB; 0.5, 1, 2, 4 kHz). Air-bone gap closure less than or equal to 10 dB was achieved in 54 cases (87%). Air-bone gap closure less than 20 dB was achieved in all cases. The average gain was 27.8 +/- 1.5 dB (SD, 12 dB; 0.5, 1, 2, 4 kHz). The average bone-conduction threshold shift or "overclosure" on 2,000 Hz was 13.6 +/- 1.3 dB (SD, 10 dB). There was no postoperative perceptive hearing loss exceeding 15 dB on any measured frequency. The Amsterdam Hearing Evaluation Plots have also been used to evaluate our data. These data were statistically analyzed and compare favorably to other published series.

CONCLUSION

The authors conclude that the combination of CO2 laser-assisted stapedotomy and the àWengen titanium clip stapes prosthesis is a combination likely to yield superior results in experienced hands.

摘要

目的

报告 CO2 激光辅助镫骨切开术联合 àWengen 钛夹镫骨假体的短期效果。与使用其他假体和/或不同镫骨切开技术的已发表系列进行比较。

研究设计

回顾性病例系列。

患者

病史和听力学数据与镫骨固定相符,且计算机断层扫描成像排除其他异常,如锤骨固定、上半规管裂、大前庭水管,这些异常可能模拟镫骨固定样听力损失。

干预

所有患者均接受 CO2 激光辅助镫骨切开术(以色列 Lumenis 公司 CO2 激光,Acuspot 712,SurgiTouch 870 扫描仪),随后采用 Heinz Kurz Medizintechnik GmbH(德国)的 àWengen 钛夹镫骨假体进行重建。

测量结果

比较和分析术前和术后听力学数据。

结果

使用 CO2 激光和 àWengen 钛夹镫骨假体进行了 62 例镫骨切开术(61 例患者)。术后 3 个月的平均气骨间隙为 5.1±0.5dB(标准差[SD]为 4.1dB;0.5、1、2、4kHz)。54 例(87%)气骨间隙闭合小于或等于 10dB。所有病例气骨间隙闭合均小于 20dB。平均增益为 27.8±1.5dB(SD 为 12dB;0.5、1、2、4kHz)。2000Hz 时平均骨导阈值移位或“过闭”为 13.6±1.3dB(SD 为 10dB)。任何测量频率均未出现超过 15dB 的术后知觉性听力损失。作者还使用阿姆斯特丹听力评估图来评估我们的数据。这些数据经过了统计学分析,与其他已发表的系列相比表现良好。

结论

作者认为,CO2 激光辅助镫骨切开术联合 àWengen 钛夹镫骨假体的组合在有经验的手中可能产生更好的效果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验