Eide T J, Nordrum I, Stalsberg H
Department of Pathology, University Hospital of Tromsøo, Norway.
Zentralbl Pathol. 1992 Dec;138(6):405-7.
To investigate the accuracy of video-microscopy of frozen sections, two pathologists reexamined 80 cases of archival material, on which frozen sections had previously been performed. Diagnoses based on the two trials (Observer 1 and 2) and diagnoses obtained in the original frozen section situation were compared with the final diagnoses based on paraffin embedded material. Observer 1 had two false negative diagnoses, but no false positive, whereas Observer 2 had one false positive, but no false negative diagnosis when compared with the final diagnoses. No false positive or false negative diagnoses were made in the original frozen sections situation and the number of inconclusive diagnoses were 5, as compared with 6 and 8 in the two trials based on video-microscopy. More experience with video-microscopy will probably achieve a quality of frozen section diagnoses similar to that of direct light-microscopy.
为研究冰冻切片视频显微镜检查的准确性,两名病理学家重新检查了80例存档材料,这些材料之前已进行过冰冻切片检查。将基于两次试验(观察者1和观察者2)的诊断结果以及原始冰冻切片情况下获得的诊断结果与基于石蜡包埋材料的最终诊断结果进行比较。与最终诊断结果相比,观察者1有两例假阴性诊断,但无假阳性诊断;而观察者2有一例假阳性诊断,但无假阴性诊断。原始冰冻切片情况下未出现假阳性或假阴性诊断,不确定诊断的数量为5例,而基于视频显微镜检查的两次试验中分别为6例和8例。更多的视频显微镜检查经验可能会使冰冻切片诊断质量达到与直接光学显微镜检查相似的水平。