Roy I M, Jefferies T M, Threadgill M D, Dewar G H
School of Pharmacy and Pharmacology, University of Bath, Claverton Down, UK.
J Pharm Biomed Anal. 1992 Oct-Dec;10(10-12):943-8. doi: 10.1016/0731-7085(91)80103-g.
The measurement of cocaine and its major metabolites has been achieved by an HPLC method that compensates for their different solubilities and detection properties. Although ecgonine methyl ester is a major metabolite it is generally not measured by HPLC because it is poorly detectable by UV, and its water solubility makes recovery from urine difficult. Using modified solid-phase extraction procedures recoveries of 85% for ecgonine methyl ester, 97% for cocaine, 106% for benzoylecgonine and 80% for ethylcocaine have been obtained from urine. Increased chromatographic retention and detection sensitivity has been obtained by formation of the t-butyldimethylsilyl derivative of ecgonine methyl ester which was found to be stable in the HPLC mobile phase for at least 1 week. Alkylation of norcocaine and benzoylecgonine has improved their detection sensitivity and also chromatographic resolution. All calibrations were linear over the range 200-1000 ng ml-1 in urine with correlation coefficients > 0.99.