Dembski J C, Decker D, Epple E, Heuck F, Zeitler E
Rofo. 1976 Jan;124(1):59-67. doi: 10.1055/s-0029-1230282.
Coronary blood flow was measured by a cine densitometric method using a newly developed system incorporating computer data analysis. The first results concerning front and wave velocity of a selectively injected contrast bolus are reported. Average absolute flow volumes in the right coronary artery are 114 ml. per minute, in the left coronary artery, 88 ml per minute (RIVA = 52 ml/min., RC = ml/min.). There is good agreement with the results of dye dilution and isotope wash out techniques, but the latter are more complicated and less easily reproduced and therefore less suitable for routine use. The results are critically evaluated.
采用一种结合计算机数据分析的新开发系统,通过电影密度测定法测量冠状动脉血流量。报告了关于选择性注射造影剂团块的前沿和波速的初步结果。右冠状动脉的平均绝对血流量为每分钟114毫升,左冠状动脉为每分钟88毫升(右心室注入量 = 52毫升/分钟,冠状动脉 = 毫升/分钟)。与染料稀释和同位素洗脱技术的结果吻合良好,但后两种技术更复杂,不易重复,因此不太适合常规使用。对结果进行了严格评估。