[铊201心肌闪烁扫描术的可靠性:与心血池造影和灌注闪烁扫描术的比较(作者译)]

[The reliability of myocardial scintigraphy with thallium201, A comparison with lacvocardiography and perfusion scintigraphy (author's transl)].

作者信息

Felix R, Pensky W, Wagner J, Thurn P, Neumann G, Hedde J P, Simon H, Winkler C

出版信息

Rofo. 1976 Mar;124(3):210-4. doi: 10.1055/s-0029-1230314.

Abstract

Eighteen patients were investigated by laevocardiography, perfusion scintigraphy and with a 201thallium scan. In four patients with normal contractility of the left ventricle, normal uptake of 202thalium was found in every patient. Hypokinesia of the anterior wall or apex of the ventricle showed normal uptake on the 201thallium scintigram in four out of five patients. It follows that it is not usually possible to diagnose hypokinetic mural portions on 201thallium scintigrams without quantitative analysis. Our experience up to date with areas of akinesia has shown that it is possible to demonstrate areas of scarring (as negative contrast) in seven out of nine cases.

摘要

对18例患者进行了左心室造影、灌注闪烁扫描及铊-201扫描。在左心室收缩功能正常的4例患者中,每例患者的铊-202摄取均正常。心室前壁或心尖运动减弱的5例患者中,有4例在铊-201闪烁扫描图上显示摄取正常。由此可见,未经定量分析,通常无法在铊-201闪烁扫描图上诊断室壁运动减弱部分。我们目前对心肌运动不能区域的经验表明,9例中有7例能够显示出瘢痕区域(呈阴性对比)。