Absorbable internal fracture fixation implants have been in large-scale clinical use since 1984. The main advantage of these devices is that no subsequent operation for implant removal is required. In this study the results obtained in a series of 600 patients with displaced malleolar fractures who were operated on over a 6-year period (1985-1990) using rods or screws made of polyglycolide were analysed. Rod fixation was used in 63% and screw fixation in 37% of the patients. Recovery was uneventful in 91.5%. Bacterial wound infection occurred in 1.2% and failure of fixation necessitating reoperation in 0.8% (5 patients). In 4 of these 5 patients a refixation procedure with AO devices was performed. In one elderly patient with failed fixation talocrural arthrodesis had to be done. A sterile inflammatory foreign-body reaction complicated the course in 6.5%. The incidence of these reactions was higher during the early years of the study, when the implants contained an aromatic quinone dye, than later, when stain-free implants were used. The foreign-body reactions were transient and did not significantly influence the ultimate results of treatment. During the 6-year period the use of absorbable implants has made it possible for resources corresponding to several hundred hardware removal procedures to be used for other purposes.

摘要

自1984年以来,可吸收性骨折内固定植入物已在临床大规模应用。这些装置的主要优点是无需后续手术取出植入物。本研究分析了1985年至1990年这6年间,600例使用聚乙交酯制成的棒材或螺钉治疗的踝关节移位骨折患者的手术结果。63%的患者采用棒材固定,37%的患者采用螺钉固定。91.5%的患者恢复顺利。伤口细菌感染发生率为1.2%,内固定失败需再次手术的发生率为0.8%(5例患者)。这5例患者中有4例采用AO器械进行了再次固定手术。1例老年患者内固定失败后不得不进行踝关节融合术。无菌性炎性异物反应使病程复杂化的发生率为6.5%。在研究初期,当植入物含有芳香醌染料时,这些反应的发生率高于后来使用无染色植入物时。异物反应是短暂的,对最终治疗结果无显著影响。在这6年期间,可吸收植入物的使用使相当于数百次取出内固定器械手术的资源得以用于其他目的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验