Kallinowski B, Gmelin K, Kommerell B, Bock H L, Clemens R, Scheiermann N, Wohland B, Hofmann F, Theilmann L
University Hospital of Heidelberg, Department of Internal Medicine IV, Germany.
Vaccine. 1992;10(8):500-1. doi: 10.1016/0264-410x(92)90346-l.
We investigated immunogenicity, reactogenicity and consistency of three consecutive lots of an inactivated hepatitis A vaccine in 204 seronegative volunteers. Each volunteer received a total of three doses of vaccine (720 EIU) according to a 0, 1 month primary vaccination schedule with a booster dose given at month 6. Mild, moderate and mostly local side effects were reported in 49.7% after the first and in less than 30% after the third injection. Seroconversion rate after one vaccine dose was as high as 91%. All subjects but one had already seroconverted by 1 month after the second injection, corresponding to a seroconversion rate of 99%. The geometric mean titres (GMT) increased with each dose of vaccine administered. Our results show that this inactivated hepatitis A vaccine is highly immunogenic, safe and well tolerated. Furthermore, there were no significant differences between the three vaccine lots in respect to seroconversion rate, size of antibody titre or reactogenicity.