Ganor E, Fischbein A, Brenner S, Froom P
Institute for Environmental Research, Sackler Faculty of Medicine, Tel Aviv University, Ramat Aviv, Israel.
Br J Ind Med. 1992 Jul;49(7):486-8. doi: 10.1136/oem.49.7.486.
Fibre concentrations of asbestos were measured in the air of a communal dining room in which the damaged ceiling had a sprayed on coating of insulation containing asbestos. The average concentration of crocidolite asbestos fibres was 4 f/cm3, 20 times the highest air concentration that appears to have been reported previously for a public building. It is concluded that although air concentrations of asbestos fibres in public buildings containing asbestos insulation materials are usually low, high concentrations can occur. This may have implications for the risk of exposed persons developing diseases associated with asbestos.
在一个公共餐厅的空气中测量了石棉纤维浓度,该餐厅天花板受损,上面喷涂了含石棉的隔热涂层。青石棉纤维的平均浓度为4根/立方厘米,是此前报道的公共建筑中最高空气浓度的20倍。得出的结论是,虽然含有石棉绝缘材料的公共建筑中石棉纤维的空气浓度通常较低,但也可能出现高浓度情况。这可能对接触者患与石棉相关疾病的风险产生影响。