Kacik W, Wienzek K
Oddziału Urazowo-Ortopedycznego Szpitala Miejskiego w Mikołowie.
Chir Narzadow Ruchu Ortop Pol. 1991;56(1-3):66-7.
The authors present a rare case of carpal tunnel syndrome caused by accessory head of palmaris longus muscle of a soft tissue tumor appearance. Clinical examination was typical for carpal tunnel syndrome. X-ray revealed no bony abnormalities. An ultrasound aided diagnosis, that was finally confirmed intra operatively and by histopathology.