Suppr超能文献

正常血糖钳夹技术在胰岛素类似物生物测定中的应用。

Application of the euglycaemic clamp technique to bioassay of insulin analogues.

作者信息

Vłlund A, Ribel U, Dam P L, Markussen J, Langkjaer L, Dolben J, Owens D R

机构信息

Novo Research Institute, Bagsvaerd, Denmark.

出版信息

Biologicals. 1992 Jun;20(2):135-42. doi: 10.1016/s1045-1056(05)80061-2.

Abstract

The euglycaemic clamp method may offer a precise and clinically valid approach to assess the in vivo potency of new insulin analogues or derivatives relative to a human insulin standard. The proposed protocol was designed to overcome problems due to differences in pharmacokinetics between the test and standard preparations. An analogue of human insulin, GlyA21+ArgB27+ThrB30-NH2, which is absorbed very slowly after subcutaneous injection, and human insulin were compared in intravenous clamp experiments in pigs. Both insulins were infused for 4 h to achieve steady state glucose metabolism. The infusion rate ranged from 2.5-8 pmol min-1 kg-1. Parallel dose response curves were obtained with the mean glucose infusion rate from 180-240 min as the response and the logarithm of the insulin infusion rate as the dose. Standard bioassay analysis showed that the molar potency of the analogue relative to human insulin was 95.2% with a 95% confidence interval of 82.3-111.2%. To assess the clinical validity of the method a similar euglycaemic clamp study was carried out in human volunteers. The insulin infusion rates were 3 and 6 pmol min-1 kg-1, and the mean glucose infusion rate over the final 180-240 min period of the clamp was used as response. The statistical analysis showed, as in the pig clamp bioassay, no significant deviations from steady state or from the assumption of parallelism. The resulting molar potency of the analogue relative to human insulin was 85.5% with a 95% confidence interval of 49.5-128.4%. This was in agreement with the result of the pig clamp bioassay.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

正常血糖钳夹法可能提供一种精确且临床有效的方法,以评估新型胰岛素类似物或衍生物相对于人胰岛素标准品的体内效力。所提出的方案旨在克服由于测试制剂和标准制剂之间药代动力学差异而产生的问题。在猪的静脉钳夹实验中,比较了皮下注射后吸收非常缓慢的人胰岛素类似物GlyA21 + ArgB27 + ThrB30 - NH2与人胰岛素。两种胰岛素均输注4小时以实现稳态葡萄糖代谢。输注速率范围为2.5 - 8 pmol min-1 kg-1。以180 - 240分钟的平均葡萄糖输注速率作为反应,胰岛素输注速率的对数作为剂量,获得了平行剂量反应曲线。标准生物测定分析表明,该类似物相对于人胰岛素的摩尔效力为95.2%,95%置信区间为82.3 - 111.2%。为了评估该方法的临床有效性,在人类志愿者中进行了类似的正常血糖钳夹研究。胰岛素输注速率为3和6 pmol min-1 kg-1,并将钳夹最后180 - 240分钟期间的平均葡萄糖输注速率用作反应。统计分析表明,与猪钳夹生物测定一样,与稳态或平行性假设无显著偏差。该类似物相对于人胰岛素的最终摩尔效力为85.5%,95%置信区间为49.5 - 128.4%。这与猪钳夹生物测定的结果一致。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验