Glass electrodes suitable for measurement of divalent cations have been made and tested. Empirical and theoretical electrode equations have been presented to describe electrode behavior in a variety of aqueous solutions. Most electrodes show response interpretable as showing nearly ideal solid-solution behavior of the cations in the glass surface. The electrodes should be useful in the measurement of divalent-cation activities in natural waters and biological fluids, and useful in general analytical chemistry.