Suppr超能文献

胎儿手术的新技术。

New techniques in fetal surgery.

作者信息

Jennings R W, Adzick N S, Longaker M T, Lorenz H P, Estes J M, Harrison M R

机构信息

Department of Surgery, University of California, San Francisco.

出版信息

J Pediatr Surg. 1992 Oct;27(10):1329-33. doi: 10.1016/0022-3468(92)90289-j.

Abstract

Optimal fetal management during and after fetal surgery has been limited by an inability to reliably monitor the fetal heart rate and temperature, and by a lack of access to the fetal circulation. In order to solve these problems, we used early third trimester fetal sheep to develop: (1) an implantable radiotelemetry device that transmits the fetal electrocardiogram and temperature, and (2) an intraosseous access technique. A miniaturized radiotelemeter was implanted subcutaneously in the axilla of four fetal sheep. Safe implantation of the radiotelemeter was technically feasible and the device reliably recorded the fetal electrocardiogram and temperature both intraoperatively and postoperatively. Although many possible routes for access to the fetal circulation have been tried experimentally and clinically for both resuscitation and blood sampling, none have proven satisfactory. We assessed the use of intraosseous access in fetal sheep (n = 6) for both infusion and blood sampling. Access with an intraosseous needle was obtained in both sheep fetuses and human fetal cadavers. Blood gas values (pH, PCO2, and PO2) obtained from the medullary cavity of fetal sheep accurately reflected peripheral venous values. Resuscitation drugs reached the fetal circulation via the intraosseous route: sodium bicarbonate elevated venous bicarbonate levels from 28.4 +/- 1.7 to 31.8 +/- 2.1 mEq/dL (P < .05); injected glucose increased venous glucose levels by 520 +/- 108 mg/dL (P < .01); and injection of calcium chloride elevated venous calcium levels from 11.8 +/- 0.7 to 15.2 +/- 2.2 mEq/dL (P < .05).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

胎儿手术期间及术后的最佳胎儿管理一直受到限制,原因在于无法可靠地监测胎儿心率和体温,以及难以进入胎儿循环系统。为了解决这些问题,我们利用妊娠晚期早期的胎羊开发了:(1)一种可植入的无线电遥测设备,用于传输胎儿心电图和体温;(2)一种骨内通路技术。将一个小型化的无线电遥测仪皮下植入四只胎羊的腋窝。无线电遥测仪的安全植入在技术上是可行的,该设备在术中及术后均能可靠地记录胎儿心电图和体温。尽管为了复苏和采血,已经在实验和临床中尝试了许多进入胎儿循环系统的可能途径,但均未证明令人满意。我们评估了在胎羊(n = 6)中使用骨内通路进行输液和采血的情况。在绵羊胎儿和人类胎儿尸体中均成功获得了骨内针通路。从胎羊骨髓腔获得的血气值(pH、PCO2和PO2)准确反映了外周静脉值。复苏药物通过骨内途径进入胎儿循环系统:碳酸氢钠使静脉碳酸氢盐水平从28.4±1.7升高至31.8±2.1 mEq/dL(P <.05);注射葡萄糖使静脉葡萄糖水平升高520±108 mg/dL(P <.01);注射氯化钙使静脉钙水平从11.8±0.7升高至15.2±2.2 mEq/dL(P <.05)。(摘要截短于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验