Nolan L M, Bowen C V, Boyer M I
Research Institute, Hospital for Sick Children, Toronto, Ontario, Canada.
Microsurgery. 1992;13(5):291-2. doi: 10.1002/micr.1920130519.
The immature rabbit knee model for epiphyseal plate transplantations has been used by a number of investigators. Rigid fixation of the femoral osteosynthesis has been difficult to achieve reliably. This paper describes a new technique for obtaining consistent and satisfactory skeletal fixation in this model. The tibia was internally fixed with an ASIF/AO four-hole minifragment plate. The femur was fixed with a 2.4 mm Steinman pin supplemented with two 26 gauge stainless steel interosseous wire loops placed at right angles to each other.
许多研究者都使用过未成熟兔膝关节骨骺板移植模型。在该模型中,可靠地实现股骨接骨术的坚固固定一直颇具难度。本文描述了一种在此模型中获得稳定且满意的骨骼固定的新技术。胫骨采用ASIF/AO四孔微型接骨板进行内固定。股骨则用一根2.4毫米的斯氏针固定,并辅以两个相互成直角放置的26号不锈钢骨间钢丝环。