Leung S F, Law M W, Ho S K
Department of Clinical Oncology, Prince of Wales Hospital, Chinese University of Hong Kong.
Br J Radiol. 1992 Oct;65(778):905-9. doi: 10.1259/0007-1285-65-778-905.
Low-dose iodine-131 of mean activity 1117 MBq was used to ablate post-operative thyroid remnants in 69 patients with differentiated thyroid cancer. Successful ablation was defined as uptake of less than 1% at 48 h and absence of visible image on the post-ablation scan. Ablation by one dose was successful in 95% of patients after total or subtotal thyroidectomy, and 56% of patients after partial or hemithyroidectomy. All patients with uptake of 10% or less on the pre-ablation scan had successful ablation. The results are compared with other reports using low-dose radioiodine ablation and the significance of the findings discussed.
采用平均活度为1117MBq的低剂量碘-131对69例分化型甲状腺癌患者的术后甲状腺残余组织进行消融。成功消融的定义为48小时时摄取率低于1%且消融后扫描无可见影像。全甲状腺切除或次全甲状腺切除术后95%的患者一次剂量消融成功,部分甲状腺切除或半甲状腺切除术后56%的患者一次剂量消融成功。所有消融前扫描摄取率为10%或更低的患者均成功消融。将结果与其他使用低剂量放射性碘消融的报告进行比较,并讨论了研究结果的意义。