In this study, the effects of high-energy shock wave (HESW) frequency on the viability of three different malignant cell lines were evaluated using a piezo-electric generator. The cell lines studied were AR42-J, VX-2 and HeLa. These cells were targeted both in free suspension and immobilised in gelatine beads. All cell lines in free suspension were acutely sensitive to HESW over a range of frequencies. When cells were immobilised in gelatine, however, the effect on cell viability was not as pronounced. However, at frequencies of 80- and 160-Hz kill rates approaching 80 and 90%, respectively, were observed. Cell proliferation following HESW treatment was not adversely affected. This study demonstrates that single cell suspensions are not appropriate for assessing the in vitro cellular effects of HESW. However, even when cells were immobilised in gelatine, high-frequency HESW produced substantial kill rates. The effects of high-frequency HESW merit further evaluation particularly using in vivo tumour.
在本研究中,使用压电发生器评估了高能冲击波(HESW)频率对三种不同恶性细胞系活力的影响。所研究的细胞系为AR42-J、VX-2和HeLa。这些细胞既在游离悬浮状态下作为靶点,也被固定在明胶珠中。所有游离悬浮的细胞系在一系列频率范围内对HESW均急性敏感。然而,当细胞被固定在明胶中时,对细胞活力的影响并不那么明显。然而,在80赫兹和160赫兹的频率下,观察到杀伤率分别接近80%和90%。HESW处理后的细胞增殖未受到不利影响。本研究表明,单细胞悬液不适用于评估HESW的体外细胞效应。然而,即使细胞被固定在明胶中,高频HESW仍产生了相当高的杀伤率。高频HESW的效应值得进一步评估,特别是在体内肿瘤模型中进行评估。